Fiber Bragg Grating Pulse and Systolic Blood Pressure Measurement System Based on Mach–Zehnder Interferometer

A fiber Bragg grating (FBG) pulse and systolic blood pressure (SBP) measurement system based on the edge-filtering method is proposed. The edge filter is the Mach-Zehnder interferometer (MZI) fabricated by two fiber couplers with a linear slope of 52.45 dBm/nm. The developed system consists of a broadband light source, an edge filter, fiber Bragg gratings (FBGs), a coarse wavelength-division multiplexer (CWDM), and signal-processing circuits based on a field-programmable gate array (FPGA). It can simultaneously measure pulse pulsations of the radial artery in the wrist at three positions: Cun, Guan and Chi. The SBP can be calculated based on the pulse transit time (PTT) principle. The measurement results compared to a standard blood pressure monitor showed the mean absolute error (MAE) and standard deviation (STD) of the SBP were 0.93 ± 3.13 mmHg. The system meets the requirements of the Association for the Advancement of Medical Instrumentation (AAMI) equipment standards. The proposed system can achieve continuous real-time measurement of pulse and SBP and has the advantages of fast detection speed, stable performance, and no compression sensation for subjects. The system has important application value in the fields of human health monitoring and medical device development.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2024-09-26
DOI
https://doi.org/10.3390/s24196222
Citations
1
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fiber Bragg Grating Pulse and Systolic Blood Pressure Measurement System Based on Mach–Zehnder Interferometer

Qianhua Li, Shanren Liu, Chao Chen, Yong‐Sen Yu et al.
1 citations
Sensors
Non-Invasive Vital Sign Monitoring
0.18
article

Fiber Bragg Grating Pulse and Systolic Blood Pressure Measurement System Based on Mach–Zehnder Interferometer

Qianhua Li, Shanren Liu, Chao Chen, Yong‐Sen Yu, Qi Guo, Yuanjun Li, Mengmeng Gao, Bo Wang
article en
1 citations

Abstract

A fiber Bragg grating (FBG) pulse and systolic blood pressure (SBP) measurement system based on the edge-filtering method is proposed. The edge filter is the Mach-Zehnder interferometer (MZI) fabricated by two fiber couplers with a linear slope of 52.45 dBm/nm. The developed system consists of a broadband light source, an edge filter, fiber Bragg gratings (FBGs), a coarse wavelength-division multiplexer (CWDM), and signal-processing circuits based on a field-programmable gate array (FPGA). It can simultaneously measure pulse pulsations of the radial artery in the wrist at three positions: Cun, Guan and Chi. The SBP can be calculated based on the pulse transit time (PTT) principle. The measurement results compared to a standard blood pressure monitor showed the mean absolute error (MAE) and standard deviation (STD) of the SBP were 0.93 ± 3.13 mmHg. The system meets the requirements of the Association for the Advancement of Medical Instrumentation (AAMI) equipment standards. The proposed system can achieve continuous real-time measurement of pulse and SBP and has the advantages of fast detection speed, stable performance, and no compression sensation for subjects. The system has important application value in the fields of human health monitoring and medical device development.

SensorsVol. 24(19)
Jilin University (CN), Chinese Academy of Sciences (CN), Changchun Institute of Optics, Fine Mechanics and Physics (CN), State Key Laboratory on Integrated Optoelectronics (CN)
Good health and well-being
Openalex Percentile: Top 52%
Non-Invasive Vital Sign Monitoring
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Fiber Bragg Grating Pulse and Systolic Blood Pressure Measurement System Based on Mach–Zehnder Interferometer — Qianhua Li, Shanren Liu, et al. · Sensors (2024) | TGRS Research Map | TGRS