Thermodynamic Assessment of A Desalination System Integrated with Combined Cycle Power Plant via Throttling Process by Using a Vapour Compressor
This study aims to conduct a thermodynamic analysis of desalination system integrated with combined cycle power plant (CCPP), with a focus on the throttling process method combined with a steam compressor, the influence of pinch point temperature difference (PPTD) on distilled water production (specific aquadest production/SAP) and specific energy consumption (SEC). Reducing condenser pressure from 10.89 to 8.43 kPa and PPTD of 10 can increase steam turbine power by 2.18% and allow the wastewater temperature to drop to 32.5°C. At a throttle valve pressure of 2.65 kPa and a mass release of water into the sea of 99.5%, steam can be condensed into distilled water with a SEC value of -1,423.36 kJ/kg with a SAP value of 3.63 kg/s under optimal conditions. In addition, a lower PPTD allows the condenser to convert vapour into liquid more efficiently due to the smaller temperature difference, resulting in more effective heat transfer.
Authors
- Muhsin Kılıç (ORCID: https://orcid.org/0000-0003-2113-4510)
- Ahmad Zikri (ORCID: https://orcid.org/0000-0002-6933-7379)
Institutions
- Bursa Uludağ Üni̇versi̇tesi̇ (TR)
- Universitas Sumatera Utara (ID)
Publication Details
- Journal
- International Journal of Exergy
- Published
- 2024-09-26
- DOI
- https://doi.org/10.1504/ijex.2025.10066839
- Primary Topic
- Solar-Powered Water Purification Methods
- Type
- article
- Field-Weighted Citation Impact
- 0.00