Hemocompatibility of promicing for ECMO high permeable polyacetylenes

A comprehensive study of hemocompatibility and gas permeability of 1,2-disubstituted polyacetylenes: poly(1-trimethylsilyl-1-propyne) and poly(4-methyl-2-pentyne) was carried out. The polymers were synthesized based on 1-trimethylsilyl-1-propyne and 4-methyl-2-pentynemonomers on the catalytic systems NbCl5 and NbCl5/n-Bu4Sn with formation of homopolymers containing 50 and 55% cis-units, respectively. The comparison of the obtained polyacetylenes and the thermoplastic polyolefin, poly(4-methyl-1-pentene), that currently is widely used as a thin-film coating of hollow fiber membranes for extracorporeal membrane oxygenation of blood (ECMO), was performed. The investigated polymers are highly hemocompatible as shown by morphofunctional status of blood cells analysis and tissue donors mesenchymal multipotent stromal bone marrow cells culture. In terms of hemocompatibility, poly(4-methyl-2-pentyne) was superior to poly(1-trimethylsilyl-1-propyne) and was comparable to poly(4-methyl-1-pentene). The studied polyacetylenes were shown to be significantly more permeable on oxygen and carbon dioxide than poly(4-methyl-1-pentene): poly(1-trimethylsilyl- 1-propyne) is permeablein 320 and 400 times, poly(4-methyl-2-pentyne) is in 60 and 90 times, respectively. Such parameters can significantly reduce the contact area of membranes with blood and reduce the size of oxygenators. Since poly(4-methyl-2-pentyne) has the high gas permeability in combination with the hemocompatibility comparable to poly(4-methyl-1-pentene), this polymer can be recommended as a promising material of a selective membrane layer for ECMO technology.

Authors

Institutions

Publication Details

Journal
Мембраны и Мембранные технологии
Published
2024-09-26
DOI
https://doi.org/10.31857/s2218117224020026
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hemocompatibility of promicing for ECMO high permeable polyacetylenes

Н. В. Боровкова, M. V. Storozheva, S. V. Zhuravel, В. П. Макрушин et al.
Мембраны и Мембранные технологии
Mechanical Circulatory Support Devices
article

Hemocompatibility of promicing for ECMO high permeable polyacetylenes

Н. В. Боровкова, M. V. Storozheva, S. V. Zhuravel, В. П. Макрушин, С. М. Матсон, A. Yu. Alentiev, М. С. Макаров, I. V. Goroncharovskaya, Н. Н. Белов, А. К. Евсеев, И. Н. Пономарев
article en

Abstract

A comprehensive study of hemocompatibility and gas permeability of 1,2-disubstituted polyacetylenes: poly(1-trimethylsilyl-1-propyne) and poly(4-methyl-2-pentyne) was carried out. The polymers were synthesized based on 1-trimethylsilyl-1-propyne and 4-methyl-2-pentynemonomers on the catalytic systems NbCl5 and NbCl5/n-Bu4Sn with formation of homopolymers containing 50 and 55% cis-units, respectively. The comparison of the obtained polyacetylenes and the thermoplastic polyolefin, poly(4-methyl-1-pentene), that currently is widely used as a thin-film coating of hollow fiber membranes for extracorporeal membrane oxygenation of blood (ECMO), was performed. The investigated polymers are highly hemocompatible as shown by morphofunctional status of blood cells analysis and tissue donors mesenchymal multipotent stromal bone marrow cells culture. In terms of hemocompatibility, poly(4-methyl-2-pentyne) was superior to poly(1-trimethylsilyl-1-propyne) and was comparable to poly(4-methyl-1-pentene). The studied polyacetylenes were shown to be significantly more permeable on oxygen and carbon dioxide than poly(4-methyl-1-pentene): poly(1-trimethylsilyl- 1-propyne) is permeablein 320 and 400 times, poly(4-methyl-2-pentyne) is in 60 and 90 times, respectively. Such parameters can significantly reduce the contact area of membranes with blood and reduce the size of oxygenators. Since poly(4-methyl-2-pentyne) has the high gas permeability in combination with the hemocompatibility comparable to poly(4-methyl-1-pentene), this polymer can be recommended as a promising material of a selective membrane layer for ECMO technology.

Мембраны и Мембранные технологииVol. 14(2)
Russian Academy of Sciences (RU), Research Institute of Emergency Care (RU), A.V. Topchiev Institute of Petrochemical Synthesis (RU)
Openalex Percentile: Top 85%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.