Comparison of size distribution and electrical particle sensor measurement methods for particle lung deposited surface area (LDSA <sup>al</sup> ) in ambient measurements with varying conditions

Abstract. It has become evident that additional metrics along the particle mass concentration, together with dense air quality monitoring networks within cities, are needed to understand the most efficient ways to tackle the health burden of particulate pollution. Particle lung-deposited surface area (LDSAal) is a metric to estimate particle exposure in the lung alveoli, and it has gained interest as a parameter for air quality monitoring as it is relatively easy and cost-efficient to measure with electrical particle sensors. Also, various studies have indicated its potential as a health-relevant metric. In addition to the electrical particle sensors, the LDSAal can be measured with various size distribution methods. However, different LDSAal measurement methods have fundamental differences in their operation principles, e.g., related to the measurement size ranges, size classification or conversion from the originally measured quantity into the LDSAal. It is not well understood how these differences affect the accuracy of the measurement in ambient conditions, where especially the particle effective density and hygroscopicity can considerably change the particle lung deposition efficiencies. In this study, the electrical particle sensor measurement (Partector) and two size distribution approaches (ELPI+ and DMPS/SMPS) were compared in road traffic environments with different environmental conditions in Helsinki and Prague. The results were compared by utilising the general assumptions of the LDSAal measurement (spherical hydrophobic particles with the standard density) and by evaluating the effects of the particle effective density and hygroscopicity. Additionally, the Partector and ELPI+ approaches were compared in various urban environments near road traffic, airports, river traffic and residential wood combustion. The results show that the comparison of different LDSAal measurement methods can be complicated in ambient measurements. The challenges were especially related to the accumulation mode particles roughly larger than 200–400 nm for which the dominant deposition mechanism in the lung changes from diffusion to impaction and the particle effective density and hygroscopicity tend to increase. On the other hand, the results suggest that the differences between the methods are reasonably low when considering only ultrafine and soot particles, which have an effective density closer to the standard (1.0 g cm−3) and are more hydrophobic, highlighting the suitability of the LDSAal as a monitored metric when estimating the spatial differences in the particulate pollution within cities.

Authors

Institutions

Publication Details

Journal
Aerosol Research
Published
2024-09-26
DOI
https://doi.org/10.5194/ar-2-271-2024
Citations
6
Primary Topic
Air Quality and Health Impacts
Type
article
Field-Weighted Citation Impact
1.89

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of size distribution and electrical particle sensor measurement methods for particle lung deposited surface area (LDSA al ) in ambient measurements with varying conditions

Jakub Ondráček, Kimmo Teinilä, Lassi Markkula, Hanna E. Manninen et al.
6 citations
Aerosol Research
Air Quality and Health Impacts
1.89
article

Comparison of size distribution and electrical particle sensor measurement methods for particle lung deposited surface area (LDSA al ) in ambient measurements with varying conditions

Jakub Ondráček, Kimmo Teinilä, Lassi Markkula, Hanna E. Manninen, Topi Rönkkö, Luis Barreira, Ville Silvonen, Teemu Lepistö, Hilkka Timonen, Miikka Dal Maso, Henna Lintusaari, Sanna Saarikoski, Jarkko V. Niemi, Laura Salo, Jussi Hoivala
article en
6 citations

Abstract

Abstract. It has become evident that additional metrics along the particle mass concentration, together with dense air quality monitoring networks within cities, are needed to understand the most efficient ways to tackle the health burden of particulate pollution. Particle lung-deposited surface area (LDSAal) is a metric to estimate particle exposure in the lung alveoli, and it has gained interest as a parameter for air quality monitoring as it is relatively easy and cost-efficient to measure with electrical particle sensors. Also, various studies have indicated its potential as a health-relevant metric. In addition to the electrical particle sensors, the LDSAal can be measured with various size distribution methods. However, different LDSAal measurement methods have fundamental differences in their operation principles, e.g., related to the measurement size ranges, size classification or conversion from the originally measured quantity into the LDSAal. It is not well understood how these differences affect the accuracy of the measurement in ambient conditions, where especially the particle effective density and hygroscopicity can considerably change the particle lung deposition efficiencies. In this study, the electrical particle sensor measurement (Partector) and two size distribution approaches (ELPI+ and DMPS/SMPS) were compared in road traffic environments with different environmental conditions in Helsinki and Prague. The results were compared by utilising the general assumptions of the LDSAal measurement (spherical hydrophobic particles with the standard density) and by evaluating the effects of the particle effective density and hygroscopicity. Additionally, the Partector and ELPI+ approaches were compared in various urban environments near road traffic, airports, river traffic and residential wood combustion. The results show that the comparison of different LDSAal measurement methods can be complicated in ambient measurements. The challenges were especially related to the accumulation mode particles roughly larger than 200–400 nm for which the dominant deposition mechanism in the lung changes from diffusion to impaction and the particle effective density and hygroscopicity tend to increase. On the other hand, the results suggest that the differences between the methods are reasonably low when considering only ultrafine and soot particles, which have an effective density closer to the standard (1.0 g cm−3) and are more hydrophobic, highlighting the suitability of the LDSAal as a monitored metric when estimating the spatial differences in the particulate pollution within cities.

Aerosol ResearchVol. 2(2)
Finnish Meteorological Institute (FI), Tampere University (FI), Aero (Czechia) (CZ)
Academy of Finland, Business Finland, Horizon 2020
Sustainable cities and communities
Openalex Percentile: Top 15%
Air Quality and Health Impacts
1.89
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.