Implementation and outcomes in benign gynecological surgery with HUGO™ RAS system 12 months initial experience

We share our experience with the Hugo™ Robotic-Assisted Surgery system in benign gynecological surgeries. We retrospectively analyzed patients who underwent elective robotic surgeries for benign gynecological conditions at our surgical center from February 2023 to February 2024. Data collected included patient demographics, surgery indications, and outcomes. Perioperative data on port-placement time, arm configurations, docking, and console time were documented. Procedural outcome data including troubleshooting and overall satisfaction were also recorded. The primary outcome was perioperative data on port placement, docking time, arm configuration, and console time. The secondary outcome was defined as team satisfaction, system troubleshooting, arm repositioning, and complications graded 3-4 on the Clavien-Dindo Scale. A total of 60 patients underwent procedures for benign gynecological conditions using the Hugo™ RAS over the 12-month study period, primarily for pelvic endometriosis (53%), hysterectomies (27%), and adnexal surgery (10%). The mean port-placement time was 13 min and 41 s. In 31% of cases, low-port placement was used, with arm positioning being asymmetrical in 63% and symmetrical in 37%, demonstrating the system's flexibility in customizing port configurations while optimizing cosmetic outcomes. Docking time averaged 5 min and 51 s, and console time was 1 h and 5 min. Operational challenges included arm tremors and limited workspace for the assistant. This study details our knowledge using the Hugo™ RAS. Learning curves of port placement, arm positioning, docking, and procedure time can be rapidly adapted in a well-trained team. Our experience suggests the technology is still in its learning curve period.

Authors

Institutions

Publication Details

Journal
Journal of Robotic Surgery
Published
2024-09-26
DOI
https://doi.org/10.1007/s11701-024-02109-z
Citations
7
Primary Topic
Uterine Myomas and Treatments
Type
article
Field-Weighted Citation Impact
4.08

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Implementation and outcomes in benign gynecological surgery with HUGO™ RAS system 12 months initial experience

Jessica Robertson, Yael Yagur, Sarah Choi, Danny Chou et al.
7 citations
Journal of Robotic Surgery
Uterine Myomas and Treatments
4.08
article

Implementation and outcomes in benign gynecological surgery with HUGO™ RAS system 12 months initial experience

Jessica Robertson, Yael Yagur, Sarah Choi, Danny Chou, Mikhail Sarofim, Martin A Martino, David Rosen, Mohammed Almoqren, Hayley Anderson
article en
7 citations

Abstract

We share our experience with the Hugo™ Robotic-Assisted Surgery system in benign gynecological surgeries. We retrospectively analyzed patients who underwent elective robotic surgeries for benign gynecological conditions at our surgical center from February 2023 to February 2024. Data collected included patient demographics, surgery indications, and outcomes. Perioperative data on port-placement time, arm configurations, docking, and console time were documented. Procedural outcome data including troubleshooting and overall satisfaction were also recorded. The primary outcome was perioperative data on port placement, docking time, arm configuration, and console time. The secondary outcome was defined as team satisfaction, system troubleshooting, arm repositioning, and complications graded 3-4 on the Clavien-Dindo Scale. A total of 60 patients underwent procedures for benign gynecological conditions using the Hugo™ RAS over the 12-month study period, primarily for pelvic endometriosis (53%), hysterectomies (27%), and adnexal surgery (10%). The mean port-placement time was 13 min and 41 s. In 31% of cases, low-port placement was used, with arm positioning being asymmetrical in 63% and symmetrical in 37%, demonstrating the system's flexibility in customizing port configurations while optimizing cosmetic outcomes. Docking time averaged 5 min and 51 s, and console time was 1 h and 5 min. Operational challenges included arm tremors and limited workspace for the assistant. This study details our knowledge using the Hugo™ RAS. Learning curves of port placement, arm positioning, docking, and procedure time can be rapidly adapted in a well-trained team. Our experience suggests the technology is still in its learning curve period.

Journal of Robotic SurgeryVol. 18(1)
Meir Medical Center (IL), UNSW Sydney (AU), St George Hospital (AU), St. Vincent's Medical Center (US)
University of New South Wales
Openalex Percentile: Top 6%
Uterine Myomas and Treatments
4.08
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.