<b>Purpose</b>: To compare anterior chamber stability and surgical efficiency in one-handed phacoemulsification, comparing Ozil and Active Sentry (AS) handpieces. <b>Methods</b>: Observational and comparative study. Selected patients were divided into two groups, AS and Ozil handpieces, and underwent one-handed phacoemulsification. Parameters like IOP per quadrant, vacuum, and aspiration flow were fixed in all surgeries. The study endpoints were intraoperative anterior chamber instability score (IACIS), cumulative dissipated energy (CDE), followability, and surgery duration. <b>Results</b>: Mean age was 71.42 years in the AS group vs. 73.97 in the Ozil Group. Mean Axial Length was 22.85 ± 1.21 mm with Active Sentry vs. 23.3 ± 1.29 mm with Ozil (<i>p</i> = 0.324). IACIS was 0.10 ± 0.30 with AS vs. 0.63 ± 0.71 with Ozil (˂0.001*). CDE was 9.95 ± 4.76 percent-seconds with AS vs. 10.89 ± 6.55 percent-seconds with Ozil (0.519). The followability score was 0.74 ± 0.855 with AS vs. 0.83 ± 0.874 with Ozil (<i>p</i> = 0.678). Surgery duration was 19.00 ± 5.44 min with AS vs. 24.57 ± 6.51 with Ozil (<i>p</i> < 0.001). <b>Conclusions</b>: The Active Sentry handpiece improves anterior chamber stability in one-handed phacoemulsification while maintaining surgical performance during nucleus removal without an auxiliary side-port. To the best of our knowledge, this is the first study demonstrating that the Active Sentry handpiece can increase anterior chamber stability not only in conventional phacoemulsification but also in one-handed phacoemulsification.

Authors

Publication Details

Journal
Diagnostics
Published
2024-09-26
DOI
https://doi.org/10.3390/diagnostics14192141
Citations
1
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
0.54
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Intraoperative Parameters between Two Handpieces in One-Handed Phacoemulsification with Active Fluidics

Rosario Gulías-Cañizo, Ana Beatriz Medina-Perez, Cyntia Solís-Hernández, Óscar Guerrero-Berger et al.
1 citations
Diagnostics
Intraocular Surgery and Lenses
0.54
article

Comparison of Intraoperative Parameters between Two Handpieces in One-Handed Phacoemulsification with Active Fluidics

Rosario Gulías-Cañizo, Ana Beatriz Medina-Perez, Cyntia Solís-Hernández, Óscar Guerrero-Berger, Jerónimo Araño-Ferrer
article en
1 citations

Abstract

<b>Purpose</b>: To compare anterior chamber stability and surgical efficiency in one-handed phacoemulsification, comparing Ozil and Active Sentry (AS) handpieces. <b>Methods</b>: Observational and comparative study. Selected patients were divided into two groups, AS and Ozil handpieces, and underwent one-handed phacoemulsification. Parameters like IOP per quadrant, vacuum, and aspiration flow were fixed in all surgeries. The study endpoints were intraoperative anterior chamber instability score (IACIS), cumulative dissipated energy (CDE), followability, and surgery duration. <b>Results</b>: Mean age was 71.42 years in the AS group vs. 73.97 in the Ozil Group. Mean Axial Length was 22.85 ± 1.21 mm with Active Sentry vs. 23.3 ± 1.29 mm with Ozil (<i>p</i> = 0.324). IACIS was 0.10 ± 0.30 with AS vs. 0.63 ± 0.71 with Ozil (˂0.001*). CDE was 9.95 ± 4.76 percent-seconds with AS vs. 10.89 ± 6.55 percent-seconds with Ozil (0.519). The followability score was 0.74 ± 0.855 with AS vs. 0.83 ± 0.874 with Ozil (<i>p</i> = 0.678). Surgery duration was 19.00 ± 5.44 min with AS vs. 24.57 ± 6.51 with Ozil (<i>p</i> < 0.001). <b>Conclusions</b>: The Active Sentry handpiece improves anterior chamber stability in one-handed phacoemulsification while maintaining surgical performance during nucleus removal without an auxiliary side-port. To the best of our knowledge, this is the first study demonstrating that the Active Sentry handpiece can increase anterior chamber stability not only in conventional phacoemulsification but also in one-handed phacoemulsification.

DiagnosticsVol. 14(19)
Affordable and clean energy
Openalex Percentile: Top 32%
Intraocular Surgery and Lenses
0.54
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.