Factors Influencing Radon Variability and Measurement Protocol Optimization in Romanian Educational Buildings Using Integrated and Continuous Measurements

Due to the higher susceptibility of children to ionizing radiation, it is imperative to evaluate the radon activity concentration (RAC) in educational buildings, conduct additional investigations to identify radon entry routes, and implement remedial measures to minimize exposure to this radioactive gas. In Romania, educational buildings are a category of public buildings where it is mandatory to perform RAC measurements. The present study examines data obtained from 41 Romanian educational buildings, where initial and additional radon investigations were performed. The first objective was to identify the factors influencing the variability of the RAC inside the buildings. The second objective was to emphasize the importance of short-term (a few days), continuous measurements in identifying buildings with RAC exceeding the reference level. High RAC values were associated with the classrooms located on the ground floor of the building compared to the administrative ones. The multiple linear regression led to a coefficient of determination of 0.11, the relative humidity and the amount of precipitation being the main variables with a significant impact, kept in the model, the lack of a significant association between the indoor RAC and the radon potential in the soil being obtained. Comparison of the radon long-term integrated measurements with continuous, short-term, led to the suggestion of three different scenarios for the measurement work protocol. By following the suggested modifications, it is possible to accelerate the procedure in situations where the time needed to plan renovations and radon remedial measures is shorter than the time needed to conduct integrated measurements.

Authors

Institutions

Publication Details

Journal
Atmosphere
Published
2024-09-26
DOI
https://doi.org/10.3390/atmos15101154
Citations
2
Primary Topic
Radioactivity and Radon Measurements
Type
article
Field-Weighted Citation Impact
0.90

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Factors Influencing Radon Variability and Measurement Protocol Optimization in Romanian Educational Buildings Using Integrated and Continuous Measurements

Tiberius Dicu, Alexandru Lupulescu, Alexandra Cucoș, Ştefan Florică et al.
2 citations
Atmosphere
Radioactivity and Radon Measurements
0.90
article

Factors Influencing Radon Variability and Measurement Protocol Optimization in Romanian Educational Buildings Using Integrated and Continuous Measurements

Tiberius Dicu, Alexandru Lupulescu, Alexandra Cucoș, Ştefan Florică, Gabriel-Cristian Dobrei, Mircea-Claudiu Moldovan, Ancuța-Cristina Țenter
article en
2 citations

Abstract

Due to the higher susceptibility of children to ionizing radiation, it is imperative to evaluate the radon activity concentration (RAC) in educational buildings, conduct additional investigations to identify radon entry routes, and implement remedial measures to minimize exposure to this radioactive gas. In Romania, educational buildings are a category of public buildings where it is mandatory to perform RAC measurements. The present study examines data obtained from 41 Romanian educational buildings, where initial and additional radon investigations were performed. The first objective was to identify the factors influencing the variability of the RAC inside the buildings. The second objective was to emphasize the importance of short-term (a few days), continuous measurements in identifying buildings with RAC exceeding the reference level. High RAC values were associated with the classrooms located on the ground floor of the building compared to the administrative ones. The multiple linear regression led to a coefficient of determination of 0.11, the relative humidity and the amount of precipitation being the main variables with a significant impact, kept in the model, the lack of a significant association between the indoor RAC and the radon potential in the soil being obtained. Comparison of the radon long-term integrated measurements with continuous, short-term, led to the suggestion of three different scenarios for the measurement work protocol. By following the suggested modifications, it is possible to accelerate the procedure in situations where the time needed to plan renovations and radon remedial measures is shorter than the time needed to conduct integrated measurements.

AtmosphereVol. 15(10)
Babeș-Bolyai University (RO)
Ministerul Cercetării, Inovării şi Digitalizării, Unitatea Executiva pentru Finantarea Invatamantului Superior, a Cercetarii, Dezvoltarii si Inovarii
Openalex Percentile: Top 26%
Radioactivity and Radon Measurements
0.90
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.