Sensitivity Approach for Blood Glucose Impedance Data Using the Geselowitz Theorem

The article presents a preclinical study focused on developing a non-invasive blood glucose monitoring device. Current glucose monitoring methods, such as capillary or venous tests, are inconvenient for frequent use, making continuous monitoring challenging. This study explores the BGP (Bruna Gabriela Pedro) model, which links electrical impedance to blood glucose levels, as a potential alternative. Using the Geselowitz Theorem and impedance spectroscopy in a 4-electrode configuration, the study investigates the relationship between blood conductivity and glucose concentration. Impedance spectra were recorded for five human blood samples with glucose concentrations between 106 and 188 mg/dL. These samples were housed in an insulating container with four stainless steel electrodes. Conductivity was calculated using the Geselowitz Theorem at 1.0, 3.9, and 24.9 kHz. A finite element model built in COMSOL was employed to assess electrode sensitivity, which had a maximum regression error of 3.75 %. The results demonstrated a sigmoid relationship between blood glucose concentration and conductivity, with impedance decreasing non-linearly as glucose levels increased. Sensitivity diminished for glucose concentrations exceeding 188 mg/dL. An increase of 82 mg/dL in glucose concentration led to conductivity changes of 1.14, 2.82, and 5.14 S/m at frequencies of 1.0, 3.9, and 24.9 kHz, respectively. The findings suggest that the BGP analytical model could be refined through the inclusion of additional data on glucose's impact on electrical impedance. These improvements could support the development of non-invasive glucose meters. The research holds significant clinical potential for the creation of a simple, cost-effective glucose monitoring device. Continuous glucose monitoring could enhance diagnostic accuracy and support better therapeutic decision-making, particularly in emergency care. The affordability and accessibility of such a device may benefit a broad patient base.

Authors

Institutions

Publication Details

Journal
Sensing and Bio-Sensing Research
Published
2024-09-27
DOI
https://doi.org/10.1016/j.sbsr.2024.100698
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sensitivity Approach for Blood Glucose Impedance Data Using the Geselowitz Theorem

Pedro Bertemes-Filho, Bruna Gabriela Pedro, John Alexander Gomez Sanchez
Sensing and Bio-Sensing Research
Spectroscopy Techniques in Biomedical and Chemical Research
article

Sensitivity Approach for Blood Glucose Impedance Data Using the Geselowitz Theorem

Pedro Bertemes-Filho, Bruna Gabriela Pedro, John Alexander Gomez Sanchez
article en

Abstract

The article presents a preclinical study focused on developing a non-invasive blood glucose monitoring device. Current glucose monitoring methods, such as capillary or venous tests, are inconvenient for frequent use, making continuous monitoring challenging. This study explores the BGP (Bruna Gabriela Pedro) model, which links electrical impedance to blood glucose levels, as a potential alternative. Using the Geselowitz Theorem and impedance spectroscopy in a 4-electrode configuration, the study investigates the relationship between blood conductivity and glucose concentration. Impedance spectra were recorded for five human blood samples with glucose concentrations between 106 and 188 mg/dL. These samples were housed in an insulating container with four stainless steel electrodes. Conductivity was calculated using the Geselowitz Theorem at 1.0, 3.9, and 24.9 kHz. A finite element model built in COMSOL was employed to assess electrode sensitivity, which had a maximum regression error of 3.75 %. The results demonstrated a sigmoid relationship between blood glucose concentration and conductivity, with impedance decreasing non-linearly as glucose levels increased. Sensitivity diminished for glucose concentrations exceeding 188 mg/dL. An increase of 82 mg/dL in glucose concentration led to conductivity changes of 1.14, 2.82, and 5.14 S/m at frequencies of 1.0, 3.9, and 24.9 kHz, respectively. The findings suggest that the BGP analytical model could be refined through the inclusion of additional data on glucose's impact on electrical impedance. These improvements could support the development of non-invasive glucose meters. The research holds significant clinical potential for the creation of a simple, cost-effective glucose monitoring device. Continuous glucose monitoring could enhance diagnostic accuracy and support better therapeutic decision-making, particularly in emergency care. The affordability and accessibility of such a device may benefit a broad patient base.

Sensing and Bio-Sensing ResearchVol. 46
Universidade do Estado de Santa Catarina (BR), ET Enterprises (United Kingdom) (GB)
Openalex Percentile: Top 89%
Spectroscopy Techniques in Biomedical and Chemical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.