X-ray spectral performance of the Sony IMX290 CMOS sensor near Fano limit after a per-pixel gain calibration
The advent of back-illuminated complementary metal–oxide–semiconductor (CMOS) sensors and their well-known advantages over charge-coupled devices make them an attractive technology for future X-ray missions. However, numerous challenges remain, including improving their depletion depth and identifying effective methods to calculate per-pixel gain conversion. We have tested a commercial Sony IMX290LLR CMOS sensor under X-ray light using an Fe55 radioactive source and collected X-ray photons for ∼15 consecutive days under stable conditions at regulated temperatures of 21°C and 26°C. At each temperature, the data set contained enough X-ray photons to produce one spectrum per pixel consisting only of single-pixel events. We determined the gain dispersion of its 2.1 million pixels using the peak fitting and the energy calibration via correlation (ECC) methods. We measured a gain dispersion of 0.4% at both temperatures and demonstrated the advantage of the ECC method in the case of spectra with low statistics. The energy resolution at 5.9 keV after the per-pixel gain correction is improved by ≳10 eV for single-pixel and all event spectra, with single-pixel event energy resolution reaching 123.6±0.2 eV, close to the Fano limit of silicon sensors at room temperature. Finally, our long data acquisition demonstrated the excellent stability of the detector over more than 30 days under a flux of 104 photons per second.
Authors
- O. Limousin (ORCID: https://orcid.org/0000-0002-7556-7605)
- Benjamin Schneider (ORCID: https://orcid.org/0000-0003-4876-7756)
- Beverly LaMarr (ORCID: https://orcid.org/0000-0001-8127-4035)
- Eric D. Miller (ORCID: https://orcid.org/0000-0002-3031-2326)
- G. Prigozhin
- Nathan P. Lourie (ORCID: https://orcid.org/0000-0002-4585-9981)
- Richard F. Foster
- Andrew Malonis
- Jill Juneau
- Catherine E. Grant (ORCID: https://orcid.org/0000-0002-4737-1373)
- Marshall W. Bautz
- Sarah Heine
- Hope Fu
Institutions
- Centre National de la Recherche Scientifique (FR)
- Université Paris Cité (FR)
- Commissariat à l'Énergie Atomique et aux Énergies Alternatives (FR)
- Université Paris-Saclay (FR)
- Astrophysique, Instrumentation et Modélisation (FR)
- CEA Paris-Saclay (FR)
- Massachusetts Institute of Technology (US)
Publication Details
- Journal
- Journal of Astronomical Telescopes Instruments and Systems
- Published
- 2024-09-28
- DOI
- https://doi.org/10.1117/1.jatis.10.3.038001
- Citations
- 1
- Primary Topic
- Advanced X-ray and CT Imaging
- Type
- article
- Field-Weighted Citation Impact
- 0.18