Detection of High-Temperature Gas Leaks in Pipelines Using Schlieren Visualization

This paper investigates the application of Schlieren flow visualization for detecting leaks in pipelines carrying high-temperature fluids. Two experimental setups were constructed: one with a 25 mm PTFE tube featuring a 2 mm diameter perforation, and another with a 100 mm diameter pipe insulated with an aluminum jacket and featuring a 12 mm leak gap. A single-mirror-off-axis Schlieren system, employing a 150 mm diameter parabolic mirror, was used to visualize the leaks. The temperature of the leaking air varied between 20 and 100 °C, while the ambient temperature was maintained at 14 °C. To quantify the leaks, the coefficient of variation for pixel intensity within the leak region was calculated. Results showed that for the PTFE tube, leaks became detectable when the temperature difference exceeded 34 °C, with the coefficient of variation surpassing 0.1. However, in the insulated pipe, detecting clear leak patterns was challenging. This research demonstrates the potential of Schlieren visualization as a valuable tool in enhancing pipeline leak detection.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2024-09-23
DOI
https://doi.org/10.3390/app14188567
Citations
1
Primary Topic
Water Systems and Optimization
Type
article
Field-Weighted Citation Impact
0.26

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detection of High-Temperature Gas Leaks in Pipelines Using Schlieren Visualization

Tae‐Jin Park, Dong‐Wook Oh, K. C. Kim
1 citations
Applied Sciences
Water Systems and Optimization
0.26
article

Detection of High-Temperature Gas Leaks in Pipelines Using Schlieren Visualization

Tae‐Jin Park, Dong‐Wook Oh, K. C. Kim
article en
1 citations

Abstract

This paper investigates the application of Schlieren flow visualization for detecting leaks in pipelines carrying high-temperature fluids. Two experimental setups were constructed: one with a 25 mm PTFE tube featuring a 2 mm diameter perforation, and another with a 100 mm diameter pipe insulated with an aluminum jacket and featuring a 12 mm leak gap. A single-mirror-off-axis Schlieren system, employing a 150 mm diameter parabolic mirror, was used to visualize the leaks. The temperature of the leaking air varied between 20 and 100 °C, while the ambient temperature was maintained at 14 °C. To quantify the leaks, the coefficient of variation for pixel intensity within the leak region was calculated. Results showed that for the PTFE tube, leaks became detectable when the temperature difference exceeded 34 °C, with the coefficient of variation surpassing 0.1. However, in the insulated pipe, detecting clear leak patterns was challenging. This research demonstrates the potential of Schlieren visualization as a valuable tool in enhancing pipeline leak detection.

Applied SciencesVol. 14(18)
Chosun University (KR), Korea Atomic Energy Research Institute (KR)
Ministry of Trade, Industry and Energy, Ministry of Science and ICT, South Korea, Korea Institute of Energy Technology Evaluation and Planning
Openalex Percentile: Top 45%
Water Systems and Optimization
0.26
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Detection of High-Temperature Gas Leaks in Pipelines Using Schlieren Visualization — Tae‐Jin Park, Dong‐Wook Oh, et al. · Applied Sciences (2024) | TGRS Research Map | TGRS