Measuring bond strength of Capsule to Fill Tube Assembly (CFTA) at cryogenic temperatures

Recent unexpected failures of capsule to fill tube assemblies fielded for NIF have prompted a revisit to study the behavior of alterna ve glue op ons and surface pretreatments to increase adhesion strength and decrease failure.The bond strength of adhesives used in NIF targets have historically been tested by a lap sheer method on Instron.However, the behaviors of materials may differ when used in such small amounts as on a CFTA as well as at different temperatures.A method and fixturing has been developed to mount a CFTA to an Instron for more accurate measurements and the ability to cool the bond with liquid nitrogen.CFTAs with 2, 5, and 10 um diameter fill tubes have been tested at 20 C and -196 C. The CFTA bond has been measured to be stronger at cryogenic temperatures.This newly developed method has shown reproducible results for measuring the bond strength of NIF target CFTAs.

Authors

Institutions

Publication Details

Journal
OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)
Published
2024-09-13
Primary Topic
Material Properties and Processing
Type
article

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measuring bond strength of Capsule to Fill Tube Assembly (CFTA) at cryogenic temperatures

Dermot E. Malone
OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)
Material Properties and Processing
article

Measuring bond strength of Capsule to Fill Tube Assembly (CFTA) at cryogenic temperatures

Dermot E. Malone
article en

Abstract

Recent unexpected failures of capsule to fill tube assemblies fielded for NIF have prompted a revisit to study the behavior of alterna ve glue op ons and surface pretreatments to increase adhesion strength and decrease failure.The bond strength of adhesives used in NIF targets have historically been tested by a lap sheer method on Instron.However, the behaviors of materials may differ when used in such small amounts as on a CFTA as well as at different temperatures.A method and fixturing has been developed to mount a CFTA to an Instron for more accurate measurements and the ability to cool the bond with liquid nitrogen.CFTAs with 2, 5, and 10 um diameter fill tubes have been tested at 20 C and -196 C. The CFTA bond has been measured to be stronger at cryogenic temperatures.This newly developed method has shown reproducible results for measuring the bond strength of NIF target CFTAs.

OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)
Lawrence Livermore National Laboratory (US)
U.S. Department of Energy, Lawrence Livermore National Laboratory
Material Properties and Processing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Measuring bond strength of Capsule to Fill Tube Assembly (CFTA) at cryogenic temperatures — Dermot E. Malone · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (2024) | TGRS Research Map | TGRS