Reliability of a Musculoskeletal Assessment for the Examination of Cervical Spine Pain and Injuries in Special Forces Combat Soldiers

An assessment of protocol reliability is an essential step prior to human subject testing for injury prevention. The purpose of this study was to examine the inter-rater and intra-rater reliability of a portable cervical range of motion and isometric strength protocol designed for special forces combat soldiers who are at risk for cervical spine pain and injury due to exposure to head-supported mass. Eight individuals were tested three times to assess reliability, the standard error of the measurement (SEM), and the minimal detectable change across six range of motion measures and six strength measures of the cervical spine. One tester tested all participants twice for intra-rater reliability, and a second tester assessed the participants to examine inter-tester reliability. All reliability measures demonstrated good to excellent reliability (ICC = 0.70-0.96 (isometric strength); ICC = 0.85-0.94 (range of motion)). All SEM scores were 12% or lower for all reliability measures. The findings of this study demonstrate that the protocol developed for a longitudinal multi-site study is reliable and appropriate to implement for injury prevention in military personnel.

Authors

Publication Details

Journal
Sports
Published
2024-09-14
DOI
https://doi.org/10.3390/sports12090255
Primary Topic
Musculoskeletal pain and rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reliability of a Musculoskeletal Assessment for the Examination of Cervical Spine Pain and Injuries in Special Forces Combat Soldiers

Ryan Zerega, Timothy C. Sell
Sports
Musculoskeletal pain and rehabilitation
article

Reliability of a Musculoskeletal Assessment for the Examination of Cervical Spine Pain and Injuries in Special Forces Combat Soldiers

Ryan Zerega, Timothy C. Sell
article en

Abstract

An assessment of protocol reliability is an essential step prior to human subject testing for injury prevention. The purpose of this study was to examine the inter-rater and intra-rater reliability of a portable cervical range of motion and isometric strength protocol designed for special forces combat soldiers who are at risk for cervical spine pain and injury due to exposure to head-supported mass. Eight individuals were tested three times to assess reliability, the standard error of the measurement (SEM), and the minimal detectable change across six range of motion measures and six strength measures of the cervical spine. One tester tested all participants twice for intra-rater reliability, and a second tester assessed the participants to examine inter-tester reliability. All reliability measures demonstrated good to excellent reliability (ICC = 0.70-0.96 (isometric strength); ICC = 0.85-0.94 (range of motion)). All SEM scores were 12% or lower for all reliability measures. The findings of this study demonstrate that the protocol developed for a longitudinal multi-site study is reliable and appropriate to implement for injury prevention in military personnel.

SportsVol. 12(9)
Good health and well-being
Openalex Percentile: Top 84%
Musculoskeletal pain and rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.