<b>Background:</b> The outstanding capabilities of modern Positron Emission Tomography (PET) to highlight small tumor lesions and provide pathological function assessment are at peril from image quality degradation caused by respiratory and cardiac motion. However, the advent of the long axial field-of-view (LAFOV) scanners with increased sensitivity, alongside the precise time-of-flight (TOF) of modern PET systems, enables the acquisition of ultrafast time resolution images, which can be used for estimating and correcting the cyclic motion. <b>Methods:</b> 0.25 s so-called [<sup>18</sup>F]FDG PET histo image series were generated in the scope of for detecting respiratory and cardiac frequency estimates applicable for performing device-less data-driven gated image reconstructions. The frequencies of the cardiac and respiratory motion were estimated for 18 patients using Short Time Fourier Transform (STFT) with 20 s and 30 s window segments, respectively. <b>Results:</b> The Fourier analysis provided time points usable as input to the gated reconstruction based on eight equally spaced time gates. The cardiac investigations showed estimates in accordance with the measured pulse oximeter references (<i>p</i> = 0.97) and a mean absolute difference of 0.4 ± 0.3 beats per minute (bpm). The respiratory frequencies were within the expected range of 10-20 respirations per minute (rpm) in 16 out of 18 patients. Using this setup, the analysis of three patients with visible lung tumors showed an increase in tumor SUV<sub>max</sub> and a decrease in tumor volume compared to the non-gated reconstructed image. <b>Conclusions:</b> The method can provide signals that were applicable for gated reconstruction of both cardiac and respiratory motion, providing a potential increased diagnostic accuracy.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2024-09-16
DOI
https://doi.org/10.3390/diagnostics14182055
Citations
2
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.81
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Device-Less Data-Driven Cardiac and Respiratory Gating Using LAFOV PET Histo Images

Jorge Cabello, Ulrich Lindberg, Flemming Littrup Andersen, Barbara Malene Fischer et al.
2 citations
Diagnostics
Medical Imaging Techniques and Applications
0.81
article

Device-Less Data-Driven Cardiac and Respiratory Gating Using LAFOV PET Histo Images

Jorge Cabello, Ulrich Lindberg, Flemming Littrup Andersen, Barbara Malene Fischer, Nanna Overbeck, N. Birge, Kirsten Korsholm, Maurizio Conti, Anders Rodell, Thomas Lund Andersen, Paul Schleyer
article en
2 citations

Abstract

<b>Background:</b> The outstanding capabilities of modern Positron Emission Tomography (PET) to highlight small tumor lesions and provide pathological function assessment are at peril from image quality degradation caused by respiratory and cardiac motion. However, the advent of the long axial field-of-view (LAFOV) scanners with increased sensitivity, alongside the precise time-of-flight (TOF) of modern PET systems, enables the acquisition of ultrafast time resolution images, which can be used for estimating and correcting the cyclic motion. <b>Methods:</b> 0.25 s so-called [<sup>18</sup>F]FDG PET histo image series were generated in the scope of for detecting respiratory and cardiac frequency estimates applicable for performing device-less data-driven gated image reconstructions. The frequencies of the cardiac and respiratory motion were estimated for 18 patients using Short Time Fourier Transform (STFT) with 20 s and 30 s window segments, respectively. <b>Results:</b> The Fourier analysis provided time points usable as input to the gated reconstruction based on eight equally spaced time gates. The cardiac investigations showed estimates in accordance with the measured pulse oximeter references (<i>p</i> = 0.97) and a mean absolute difference of 0.4 ± 0.3 beats per minute (bpm). The respiratory frequencies were within the expected range of 10-20 respirations per minute (rpm) in 16 out of 18 patients. Using this setup, the analysis of three patients with visible lung tumors showed an increase in tumor SUV<sub>max</sub> and a decrease in tumor volume compared to the non-gated reconstructed image. <b>Conclusions:</b> The method can provide signals that were applicable for gated reconstruction of both cardiac and respiratory motion, providing a potential increased diagnostic accuracy.

DiagnosticsVol. 14(18)
Copenhagen University Hospital (DK), Rigshospitalet (DK), Siemens (Denmark) (DK), Siemens (United States) (US)
Good health and well-being
Openalex Percentile: Top 26%
Medical Imaging Techniques and Applications
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.