Using a Time-of-Travel Sampling Approach to Quantify Per- and Polyfluoroalkyl Substances (PFAS) Stream Loading and Source Inputs in a Mixed-Source, Urban Catchment

Understanding per- and polyfluoroalkyl substances (PFAS) mass distribution in surface and groundwater systems can support source prioritization, load reduction, and water management. Thirteen sites within an urban catchment were sampled utilizing a time-of-travel sampling approach to minimize the influence of subdaily fluctuations in mass from PFAS point sources and to quantify PFAS and ancillary chemical loads from various PFAS sources. A larger increase in perfluoroalkyl sulfonate (PFSA) loads (8 to 11 μg/s, up to 618%) than in perfluoroalkyl carboxylate (PFCA) loads (no change to 3.4 μg/s, up to 122%) was observed at sites below tributaries influenced by military bases with known groundwater discharge. Point discharges from two sewage treatment plants (STPs) resulted in increases in PFCA and PFSA loads that were similar (6 and 10 μg/s respectively) below the first STP and greater for PFCA compared to PFSA loads (23 and 13 μg/s respectively) below the second STP. Overall, percent increases in total PFAS load ranged from 20 to 277% for military base inputs and 44 to 77% for STP inputs. A focus catchment that represents only 14% (76.9 km2) of the drainage area at the most downstream site (544 km2) accounted for about 70% of PFSA and 40% of PFCA loads observed at the most downstream site. Results show that by using a time-of-travel sampling approach in mixed, urban settings with several PFAS sources, it is possible to quantify stream loads from individual PFAS sources, thereby improving source attribution and providing actionable data for water-resource managers.

Authors

Institutions

Publication Details

Journal
ACS ES&T Water
Published
2024-09-16
DOI
https://doi.org/10.1021/acsestwater.4c00288
Citations
6
Primary Topic
Per- and polyfluoroalkyl substances research
Type
article
Field-Weighted Citation Impact
1.50

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Using a Time-of-Travel Sampling Approach to Quantify Per- and Polyfluoroalkyl Substances (PFAS) Stream Loading and Source Inputs in a Mixed-Source, Urban Catchment

Joseph W. Duris, Jacob A. Fleck, Angela M. Hansen, Larry B. Barber et al.
6 citations
ACS ES&T Water
Per- and polyfluoroalkyl substances research
1.50
article

Using a Time-of-Travel Sampling Approach to Quantify Per- and Polyfluoroalkyl Substances (PFAS) Stream Loading and Source Inputs in a Mixed-Source, Urban Catchment

Joseph W. Duris, Jacob A. Fleck, Angela M. Hansen, Larry B. Barber, Lisa A. Senior, Emily E. Woodward
article en
6 citations

Abstract

Understanding per- and polyfluoroalkyl substances (PFAS) mass distribution in surface and groundwater systems can support source prioritization, load reduction, and water management. Thirteen sites within an urban catchment were sampled utilizing a time-of-travel sampling approach to minimize the influence of subdaily fluctuations in mass from PFAS point sources and to quantify PFAS and ancillary chemical loads from various PFAS sources. A larger increase in perfluoroalkyl sulfonate (PFSA) loads (8 to 11 μg/s, up to 618%) than in perfluoroalkyl carboxylate (PFCA) loads (no change to 3.4 μg/s, up to 122%) was observed at sites below tributaries influenced by military bases with known groundwater discharge. Point discharges from two sewage treatment plants (STPs) resulted in increases in PFCA and PFSA loads that were similar (6 and 10 μg/s respectively) below the first STP and greater for PFCA compared to PFSA loads (23 and 13 μg/s respectively) below the second STP. Overall, percent increases in total PFAS load ranged from 20 to 277% for military base inputs and 44 to 77% for STP inputs. A focus catchment that represents only 14% (76.9 km2) of the drainage area at the most downstream site (544 km2) accounted for about 70% of PFSA and 40% of PFCA loads observed at the most downstream site. Results show that by using a time-of-travel sampling approach in mixed, urban settings with several PFAS sources, it is possible to quantify stream loads from individual PFAS sources, thereby improving source attribution and providing actionable data for water-resource managers.

ACS ES&T WaterVol. 4(10)
United States Geological Survey (US), California Water Science Center, Pennsylvania Water Science Center
Pennsylvania Department of Environmental Protection, U.S. Geological Survey
Sustainable cities and communities
Openalex Percentile: Top 20%
Per- and polyfluoroalkyl substances research
1.50
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.