Mimicking large spot‐scanning radiation fields for proton FLASH preclinical studies with a robotic motion platform

Previously, a synchrotron-based horizontal proton beamline (87.2 MeV) was successfully commissioned to deliver radiation doses in FLASH and conventional dose rate modes to small fields and volumes. In this study, we developed a strategy to increase the effective radiation field size using a custom robotic motion platform to automatically shift the positions of biological samples. The beam was first broadened with a thin tungsten scatterer and shaped by customized brass collimators for irradiating cell/organoid cultures in 96-well plates (a 7-mm-diameter circle) or for irradiating mice (1-cm<sup>2</sup> square). Motion patterns of the robotic platform were written in G-code, with 9-mm spot spacing used for the 96-well plates and 10.6-mm spacing for the mice. The accuracy of target positioning was verified with a self-leveling laser system. The dose delivered in the experimental conditions was validated with EBT-XD film attached to the 96-well plate or the back of the mouse. Our film-measured dose profiles matched Monte Carlo calculations well (1D gamma pass rate >95%). The FLASH dose rates were 113.7 Gy/s for cell/organoid irradiation and 191.3 Gy/s for mouse irradiation. These promising results indicate that this robotic platform can be used to effectively increase the field size for preclinical experiments with proton FLASH.

Authors

Institutions

Publication Details

Journal
Precision Radiation Oncology
Published
2024-10-24
DOI
https://doi.org/10.1002/pro6.1243
Citations
4
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
1.68

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mimicking large spot‐scanning radiation fields for proton FLASH preclinical studies with a robotic motion platform

Kiminori Iga, Julianna Bronk, N Sahoo, David R. Grosshans et al.
4 citations
Precision Radiation Oncology
Radiation Therapy and Dosimetry
1.68
article

Mimicking large spot‐scanning radiation fields for proton FLASH preclinical studies with a robotic motion platform

Kiminori Iga, Julianna Bronk, N Sahoo, David R. Grosshans, Radhe Mohan, Dadi Jiang, Lawrence F. Bronk, Ming Yang, Albert C. Koong, Fada Guan, Yuting Li, Xiaochun Wang, Youming Guo, Xiaorong R. Zhu, Liang Wang
article en
4 citations

Abstract

Previously, a synchrotron-based horizontal proton beamline (87.2 MeV) was successfully commissioned to deliver radiation doses in FLASH and conventional dose rate modes to small fields and volumes. In this study, we developed a strategy to increase the effective radiation field size using a custom robotic motion platform to automatically shift the positions of biological samples. The beam was first broadened with a thin tungsten scatterer and shaped by customized brass collimators for irradiating cell/organoid cultures in 96-well plates (a 7-mm-diameter circle) or for irradiating mice (1-cm<sup>2</sup> square). Motion patterns of the robotic platform were written in G-code, with 9-mm spot spacing used for the 96-well plates and 10.6-mm spacing for the mice. The accuracy of target positioning was verified with a self-leveling laser system. The dose delivered in the experimental conditions was validated with EBT-XD film attached to the 96-well plate or the back of the mouse. Our film-measured dose profiles matched Monte Carlo calculations well (1D gamma pass rate >95%). The FLASH dose rates were 113.7 Gy/s for cell/organoid irradiation and 191.3 Gy/s for mouse irradiation. These promising results indicate that this robotic platform can be used to effectively increase the field size for preclinical experiments with proton FLASH.

Precision Radiation OncologyVol. 8(4)
The University of Texas MD Anderson Cancer Center (US), Hitachi Global Storage Technologies (United States) (US)
University of Texas at Austin, Department of Mechanical Engineering, University of Texas at Austin, University of Texas MD Anderson Cancer Center, National Cancer Institute
Openalex Percentile: Top 15%
Radiation Therapy and Dosimetry
1.68
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.