Mimicking large spot‐scanning radiation fields for proton FLASH preclinical studies with a robotic motion platform
Previously, a synchrotron-based horizontal proton beamline (87.2 MeV) was successfully commissioned to deliver radiation doses in FLASH and conventional dose rate modes to small fields and volumes. In this study, we developed a strategy to increase the effective radiation field size using a custom robotic motion platform to automatically shift the positions of biological samples. The beam was first broadened with a thin tungsten scatterer and shaped by customized brass collimators for irradiating cell/organoid cultures in 96-well plates (a 7-mm-diameter circle) or for irradiating mice (1-cm<sup>2</sup> square). Motion patterns of the robotic platform were written in G-code, with 9-mm spot spacing used for the 96-well plates and 10.6-mm spacing for the mice. The accuracy of target positioning was verified with a self-leveling laser system. The dose delivered in the experimental conditions was validated with EBT-XD film attached to the 96-well plate or the back of the mouse. Our film-measured dose profiles matched Monte Carlo calculations well (1D gamma pass rate >95%). The FLASH dose rates were 113.7 Gy/s for cell/organoid irradiation and 191.3 Gy/s for mouse irradiation. These promising results indicate that this robotic platform can be used to effectively increase the field size for preclinical experiments with proton FLASH.
Authors
- Kiminori Iga
- Julianna Bronk (ORCID: https://orcid.org/0000-0003-3459-1833)
- N Sahoo
- David R. Grosshans
- Radhe Mohan (ORCID: https://orcid.org/0000-0003-3746-4557)
- Dadi Jiang (ORCID: https://orcid.org/0000-0002-0935-3908)
- Lawrence F. Bronk (ORCID: https://orcid.org/0000-0001-6798-1788)
- Ming Yang (ORCID: https://orcid.org/0000-0001-9122-0401)
- Albert C. Koong (ORCID: https://orcid.org/0000-0001-9824-1643)
- Fada Guan (ORCID: https://orcid.org/0000-0001-8477-7391)
- Yuting Li (ORCID: https://orcid.org/0000-0002-6716-358X)
- Xiaochun Wang (ORCID: https://orcid.org/0000-0002-8897-5077)
- Youming Guo (ORCID: https://orcid.org/0000-0002-4782-2090)
- Xiaorong R. Zhu
- Liang Wang (ORCID: https://orcid.org/0009-0008-4662-2370)
Institutions
- The University of Texas MD Anderson Cancer Center (US)
- Hitachi Global Storage Technologies (United States) (US)
Publication Details
- Journal
- Precision Radiation Oncology
- Published
- 2024-10-24
- DOI
- https://doi.org/10.1002/pro6.1243
- Citations
- 4
- Primary Topic
- Radiation Therapy and Dosimetry
- Type
- article
- Field-Weighted Citation Impact
- 1.68
Funders
- University of Texas at Austin
- Department of Mechanical Engineering, University of Texas at Austin
- University of Texas MD Anderson Cancer Center
- National Cancer Institute