Real Power Losses Reduced by Network Reconfiguration the Distribution Systems using Modified BAT Algorithm

This research paper is proposed to achieving the minimum power losses in all the branches, minimum number of switching operations, maximizing the power flow through the placing the DG sources, minimizing the voltage deviations with satisfying all the constraints using the modified BAT algorithm. The effect of the offered method is tested on standard systems like IEEE 33, 69 buses and Indian standard 62 bus distribution systems. The mBAT effect is estimated with the recent algorithm including Shuffled Frog, Stud krill, Dingo, Grey Wolf, and Antlion algorithms. MATLAB results are proved that the total power active power losses and branch voltages and number of switches, capacity of DG sources and cost of the DG sources are drastically reduced. The results are compared with many techniques are tabulated. Moreover, the mBAT algorithm is more superior and confirmed with other animal-related algorithms like Antlion, Grey wolf, Gross Hopper, Dingo, sturd Krill, cuckoo crunch algorithm and Shuffled Frog algorithms. In view of more speed of convergence and high accuracy and processed in less number repetition. Also, the results of the proposed techniques are encouraging and helpful to future research.

Authors

Institutions

Publication Details

Journal
International Journal of Electrical and Electronics Research
Published
2024-08-10
DOI
https://doi.org/10.37391/ijeer.120319
Primary Topic
Optimal Power Flow Distribution
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real Power Losses Reduced by Network Reconfiguration the Distribution Systems using Modified BAT Algorithm

V. Nandagopal, N. Sivakamasundari, R. Kavin, P. Sundararaman
International Journal of Electrical and Electronics Research
Optimal Power Flow Distribution
article

Real Power Losses Reduced by Network Reconfiguration the Distribution Systems using Modified BAT Algorithm

V. Nandagopal, N. Sivakamasundari, R. Kavin, P. Sundararaman
article en

Abstract

This research paper is proposed to achieving the minimum power losses in all the branches, minimum number of switching operations, maximizing the power flow through the placing the DG sources, minimizing the voltage deviations with satisfying all the constraints using the modified BAT algorithm. The effect of the offered method is tested on standard systems like IEEE 33, 69 buses and Indian standard 62 bus distribution systems. The mBAT effect is estimated with the recent algorithm including Shuffled Frog, Stud krill, Dingo, Grey Wolf, and Antlion algorithms. MATLAB results are proved that the total power active power losses and branch voltages and number of switches, capacity of DG sources and cost of the DG sources are drastically reduced. The results are compared with many techniques are tabulated. Moreover, the mBAT algorithm is more superior and confirmed with other animal-related algorithms like Antlion, Grey wolf, Gross Hopper, Dingo, sturd Krill, cuckoo crunch algorithm and Shuffled Frog algorithms. In view of more speed of convergence and high accuracy and processed in less number repetition. Also, the results of the proposed techniques are encouraging and helpful to future research.

International Journal of Electrical and Electronics ResearchVol. 12(3)
Hindustan Institute of Technology and Science (IN), GITAM University (IN)
Openalex Percentile: Top 86%
Optimal Power Flow Distribution
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.