A Fault-Tolerant Single-Phase Inverter Using Redundant Leg

Single-phase inverters are increasingly used in a variety of applications from renewable energy systems to un-interruptible power supply. In the design and operation of these inverters, reliability remains a major concern. The single-phase inverter offers fault tolerance by including a redundant leg. The conventional redundant leg configuration uses four triode for alternating current (TRIAC) and two switches. The voltage seen across TRIACs used to connect the redundant leg is pulse width modulated (PWM). The high dv/dt across the TRIACs in the conventional topology due to PWM causes spurious turn ON across TRIACs. It leads to a short-circuit (SC) across the terminals. Thus, there is a need to modify the conventional TRIAC arrangement that is used to connect the redundant leg. In this paper, an updated TRIAC arrangement for a fault-tolerant single-phase inverter is proposed. The proposed TRIAC arrangement uses a split inductor filter to provide a sinusoidal voltage across the TRIACs. Thus the rearrangement of TRIAC ensures the lower dv/dt across the terminals. The reconfiguration of TRIACs is verified in simulation and experimentally through a 200V single-phase inverter with redundant leg prototype.

Authors

Institutions

Publication Details

Published
2024-08-04
DOI
https://doi.org/10.1109/intelec60315.2024.10679020
Primary Topic
Multilevel Inverters and Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Fault-Tolerant Single-Phase Inverter Using Redundant Leg

Priya Singh Bhakar, J. Kalaisel, Ankita Tripathi
Multilevel Inverters and Converters
article

A Fault-Tolerant Single-Phase Inverter Using Redundant Leg

Priya Singh Bhakar, J. Kalaisel, Ankita Tripathi
article en

Abstract

Single-phase inverters are increasingly used in a variety of applications from renewable energy systems to un-interruptible power supply. In the design and operation of these inverters, reliability remains a major concern. The single-phase inverter offers fault tolerance by including a redundant leg. The conventional redundant leg configuration uses four triode for alternating current (TRIAC) and two switches. The voltage seen across TRIACs used to connect the redundant leg is pulse width modulated (PWM). The high dv/dt across the TRIACs in the conventional topology due to PWM causes spurious turn ON across TRIACs. It leads to a short-circuit (SC) across the terminals. Thus, there is a need to modify the conventional TRIAC arrangement that is used to connect the redundant leg. In this paper, an updated TRIAC arrangement for a fault-tolerant single-phase inverter is proposed. The proposed TRIAC arrangement uses a split inductor filter to provide a sinusoidal voltage across the TRIACs. Thus the rearrangement of TRIAC ensures the lower dv/dt across the terminals. The reconfiguration of TRIACs is verified in simulation and experimentally through a 200V single-phase inverter with redundant leg prototype.

Indian Institute of Technology Ropar (IN)
Affordable and clean energy
Openalex Percentile: Top 86%
Multilevel Inverters and Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Fault-Tolerant Single-Phase Inverter Using Redundant Leg — Priya Singh Bhakar, J. Kalaisel, et al. · (2024) | TGRS Research Map | TGRS