Analysis of Stray Capacitance Effects in Dynamics of LLC Converters under PFM for Battery Charging

In digital voltage mode-controlled LLC converter under pulse frequency modulation (PFM), a PID controller needs to be designed to achieve adequate transient performance under step changes in reference voltage, load current, and/or input voltage. However, the unevenly distributed high-frequency ringing and unpredictable voltage regulation issues caused by the stray capacitances cannot be predicted using the traditional fundamental harmonic approximation approach, which may lead to malfunctioning of the circuit components, degrade the transformer's lifespan, and cause devastating effects on the entire system. This paper highlights the typical potential threat that stray capacitances may introduce to the closed-loop dynamics of LLC converter and addresses the feasible degrees of freedom in order to minimize their influence on the converter's performance over a wide operating condition. Analytical predictions are verified using simulation results, and the performance improvement by conditionally adopting the dead time adjustment along with robust controller design is presented.

Authors

Institutions

Publication Details

Published
2024-08-04
DOI
https://doi.org/10.1109/intelec60315.2024.10678993
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Stray Capacitance Effects in Dynamics of LLC Converters under PFM for Battery Charging

Dipayan Chatterjee, Ranajay Mallik, Indra Narayan Kar, Santanu Kapat
High-Voltage Power Transmission Systems
article

Analysis of Stray Capacitance Effects in Dynamics of LLC Converters under PFM for Battery Charging

Dipayan Chatterjee, Ranajay Mallik, Indra Narayan Kar, Santanu Kapat
article en

Abstract

In digital voltage mode-controlled LLC converter under pulse frequency modulation (PFM), a PID controller needs to be designed to achieve adequate transient performance under step changes in reference voltage, load current, and/or input voltage. However, the unevenly distributed high-frequency ringing and unpredictable voltage regulation issues caused by the stray capacitances cannot be predicted using the traditional fundamental harmonic approximation approach, which may lead to malfunctioning of the circuit components, degrade the transformer's lifespan, and cause devastating effects on the entire system. This paper highlights the typical potential threat that stray capacitances may introduce to the closed-loop dynamics of LLC converter and addresses the feasible degrees of freedom in order to minimize their influence on the converter's performance over a wide operating condition. Analytical predictions are verified using simulation results, and the performance improvement by conditionally adopting the dead time adjustment along with robust controller design is presented.

Indian Institute of Technology Kharagpur (IN), STMicroelectronics (India) (IN), Indian Institute of Technology Delhi (IN)
Affordable and clean energy
Openalex Percentile: Top 86%
High-Voltage Power Transmission Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.