Characterization of ferrous-xylenol orange-polyvinyl alcohol gel for gamma dosimetry using spectroscopy

Abstract Fricke gel dosimeters are appropriate candidates for gamma dosimetry. Polyvinyl alcohol Fricke gel dosimeters are the most recent introduced gel dosimeters which have low ion diffusion. In this work, samples of ferrous-xylenol orange-polyvinyl alcohol gel dosimeters were prepared and characterized using optical spectroscopy. Using win XCOM program and the elemental composition of the gel, the mass attenuation coefficients for photons were evaluated. The results exhibited that the prepared gel is the nearly radiological blood-, soft tissue- and water-equivalent. The 60 Co gamma cell unit was used to irradiate the gel samples. A dose range response was found linear from 10 to 30 Gy and suitable for blood irradiation dosimetry. Additionally, the gel response good repeatability was confirmed by the coefficient of variation calculations. Furthermore, chemical yield of the gel was estimated to be 34.6. The good characteristics of the prepared gel make it appropriate for dosimetry of blood irradiators.

Authors

Institutions

Publication Details

Journal
Radiochimica Acta
Published
2024-09-16
DOI
https://doi.org/10.1515/ract-2024-0284
Citations
2
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
1.22
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Characterization of ferrous-xylenol orange-polyvinyl alcohol gel for gamma dosimetry using spectroscopy

Payvand Taherparvar, Elham Edalatkhah, Mahsa Sedighi
2 citations
Radiochimica Acta
Advanced Radiotherapy Techniques
1.22
article

Characterization of ferrous-xylenol orange-polyvinyl alcohol gel for gamma dosimetry using spectroscopy

Payvand Taherparvar, Elham Edalatkhah, Mahsa Sedighi
article en
2 citations

Abstract

Abstract Fricke gel dosimeters are appropriate candidates for gamma dosimetry. Polyvinyl alcohol Fricke gel dosimeters are the most recent introduced gel dosimeters which have low ion diffusion. In this work, samples of ferrous-xylenol orange-polyvinyl alcohol gel dosimeters were prepared and characterized using optical spectroscopy. Using win XCOM program and the elemental composition of the gel, the mass attenuation coefficients for photons were evaluated. The results exhibited that the prepared gel is the nearly radiological blood-, soft tissue- and water-equivalent. The 60 Co gamma cell unit was used to irradiate the gel samples. A dose range response was found linear from 10 to 30 Gy and suitable for blood irradiation dosimetry. Additionally, the gel response good repeatability was confirmed by the coefficient of variation calculations. Furthermore, chemical yield of the gel was estimated to be 34.6. The good characteristics of the prepared gel make it appropriate for dosimetry of blood irradiators.

Radiochimica ActaVol. 112(11)
Nuclear Science and Technology Research Institute, University of Guilan (IR)
Clean water and sanitation
Openalex Percentile: Top 21%
Advanced Radiotherapy Techniques
1.22
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.