Abstract The measurement of focal spot sizes in industrial x‐ray tubes using conventional edge and slit methods typically requires complex slit diaphragms and auxiliary testing equipment. Additionally, stringent spatial‐positioning requirements are imposed on the x‐ray tube, auxiliary testing equipment, and detector, making the machining of auxiliary testing equipment and meeting test conditions challenging. This study optimized and improved the auxiliary testing equipment and computations in the slit method based on the principles of the edge method. An experimental setup capable of self‐calibrating the spatial positions was designed, avoiding measurement errors during focal‐spot‐size measurements. We derived a formula for the focal spot size for this experimental setup, allowing measurements using slits of various sizes. Furthermore, we proposed a method for determining the focal spot size through linear fitting of multiple sets of slit dimensions and projected widths of the focal spot on the detector. This approach filters out random noise and errors during data collection, significantly enhancing measurement precision. By adjusting the slit and detector angles, we could measure the focal spot sizes at various angles and draw contour maps of the focal spot shape. This method was applied to measure the focal spot size and shape of a side‐window x‐ray tube under different voltage conditions. The overall measurement error was less than 6%, reflecting the reliability, accuracy, and consistency of the results obtained using the proposed method. Thus, the proposed method supports the inspection, verification, and maintenance of x‐ray sources.

Authors

Institutions

Publication Details

Journal
X-Ray Spectrometry
Published
2024-09-16
DOI
https://doi.org/10.1002/xrs.3452
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhanced slit methodology for characterization of x‐ray focal properties

Dazheng Wang, Han Li, Chu Mingzhang
X-Ray Spectrometry
Advanced X-ray Imaging Techniques
article

Enhanced slit methodology for characterization of x‐ray focal properties

Dazheng Wang, Han Li, Chu Mingzhang
article en

Abstract

Abstract The measurement of focal spot sizes in industrial x‐ray tubes using conventional edge and slit methods typically requires complex slit diaphragms and auxiliary testing equipment. Additionally, stringent spatial‐positioning requirements are imposed on the x‐ray tube, auxiliary testing equipment, and detector, making the machining of auxiliary testing equipment and meeting test conditions challenging. This study optimized and improved the auxiliary testing equipment and computations in the slit method based on the principles of the edge method. An experimental setup capable of self‐calibrating the spatial positions was designed, avoiding measurement errors during focal‐spot‐size measurements. We derived a formula for the focal spot size for this experimental setup, allowing measurements using slits of various sizes. Furthermore, we proposed a method for determining the focal spot size through linear fitting of multiple sets of slit dimensions and projected widths of the focal spot on the detector. This approach filters out random noise and errors during data collection, significantly enhancing measurement precision. By adjusting the slit and detector angles, we could measure the focal spot sizes at various angles and draw contour maps of the focal spot shape. This method was applied to measure the focal spot size and shape of a side‐window x‐ray tube under different voltage conditions. The overall measurement error was less than 6%, reflecting the reliability, accuracy, and consistency of the results obtained using the proposed method. Thus, the proposed method supports the inspection, verification, and maintenance of x‐ray sources.

X-Ray SpectrometryVol. 54(3)
Chinese Academy of Sciences (CN), Institute of Electrical Engineering (CN), University of Chinese Academy of Sciences (CN), Xi'an Jiaotong University (CN)
Key Technologies Research and Development Program
Openalex Percentile: Top 79%
Advanced X-ray Imaging Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Enhanced slit methodology for characterization of x‐ray focal properties — Dazheng Wang, Han Li, et al. · X-Ray Spectrometry (2024) | TGRS Research Map | TGRS