Room temperature dual-mode internal quantum deficiency measurement with propagated uncertainty to 0.03% (k=2)

Abstract We present improvements in dual-mode calibration of predictable quantum efficient detectors (PQED) and demonstrate the importance of calculating absolute uncertainties instead of relative uncertainties. We have implemented a new uncertainty component for the thermal fluctuations in the temperature signal which results in a propagated Type A uncertainty, matching the observed standard deviation. A new thermal drift correction method exploiting a monitor thermistor on the heat sink is relaxing the need for thermal stabilisation of the experimental set-up. With beam position uncertainty ± 0.25 mm and background electrical power varying from 10 μW to 900 μW, the measured internal quantum deficiency (IQD) is in average 0.00% ± 0.03% (k=2). The IQD exhibits clear systematic effects of beam position and background power, showing the need for improved design of dual-mode modules to further improve the uncertainty.

Authors

Institutions

Publication Details

Journal
Metrologia
Published
2024-09-16
DOI
https://doi.org/10.1088/1681-7575/ad7b24
Primary Topic
Quantum Information and Cryptography
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Room temperature dual-mode internal quantum deficiency measurement with propagated uncertainty to 0.03% (k=2)

Eivind Bardalen, Jarle Gran, Johanne Heitmann Solheim
Metrologia
Quantum Information and Cryptography
article

Room temperature dual-mode internal quantum deficiency measurement with propagated uncertainty to 0.03% (k=2)

Eivind Bardalen, Jarle Gran, Johanne Heitmann Solheim
article en

Abstract

Abstract We present improvements in dual-mode calibration of predictable quantum efficient detectors (PQED) and demonstrate the importance of calculating absolute uncertainties instead of relative uncertainties. We have implemented a new uncertainty component for the thermal fluctuations in the temperature signal which results in a propagated Type A uncertainty, matching the observed standard deviation. A new thermal drift correction method exploiting a monitor thermistor on the heat sink is relaxing the need for thermal stabilisation of the experimental set-up. With beam position uncertainty ± 0.25 mm and background electrical power varying from 10 μW to 900 μW, the measured internal quantum deficiency (IQD) is in average 0.00% ± 0.03% (k=2). The IQD exhibits clear systematic effects of beam position and background power, showing the need for improved design of dual-mode modules to further improve the uncertainty.

Metrologia
University of South-Eastern Norway (NO), Norwegian Metrology Service (NO)
European Commission, HORIZON EUROPE Framework Programme, European Metrology Programme for Innovation and Research
Openalex Percentile: Top 86%
Quantum Information and Cryptography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Room temperature dual-mode internal quantum deficiency measurement with propagated uncertainty to 0.03% (k=2) — Eivind Bardalen, Jarle Gran, et al. · Metrologia (2024) | TGRS Research Map | TGRS