Development of a Novel High Temperature Continuous Particle Mass Flow Measurement Device for Particle-Based CSP Applications

Particle-based concentrating solar power (CSP) technology is one of the generation three (Gen3) CSP technologies that has potential for lowering the levelized cost of electricity produced by this solar thermal power systems. Commercially available ceramic particles, which are rated for high temperature applications up to 1200 °C, were selected for this study. This medium is commonly used as an energy carrier or heat transfer medium in Gen3 CSP research and development efforts [1]. Prior studies at the National Solar Thermal Test Facility (NSTTF) have investigated and evaluated various mass flow measurement methods, and a simple gravimetric temporal load measurement method was chosen as the best candidate for the research purpose [2]. This mass flow measurement method is a batch process and is not a viable solution for commercial-scale power generation applications based on cost, space, process control, and practical system integration factors. In-line and continuous particle mass flow measurement will play an integral role in efficient and cost effective Gen3 CSP particle technologies. Process parameters, including energy absorbed by the particles, receiver efficiency, temperature dependent flow phenomena, and general high temperature measurement reliability are all rely on repeatable and accurate measurement of particle mass flow under various operating conditions. Ceramic particles, like those used in this application, are not conventionally used as an energy carrier. A novel concept for continuous particle mass flow at a wide range of operating temperatures is currently under development and planned to be tested at the NSTTF, called the Particle In-LinE (PILE) mass flow sensor.

Authors

Institutions

Publication Details

Journal
SolarPACES Conference Proceedings
Published
2024-09-16
DOI
https://doi.org/10.52825/solarpaces.v2i.915
Primary Topic
Cyclone Separators and Fluid Dynamics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a Novel High Temperature Continuous Particle Mass Flow Measurement Device for Particle-Based CSP Applications

Hendrik Laubscher, Luke McLaughlin, Kaden Plewe, Samuel C Hastings
SolarPACES Conference Proceedings
Cyclone Separators and Fluid Dynamics
article

Development of a Novel High Temperature Continuous Particle Mass Flow Measurement Device for Particle-Based CSP Applications

Hendrik Laubscher, Luke McLaughlin, Kaden Plewe, Samuel C Hastings
article en

Abstract

Particle-based concentrating solar power (CSP) technology is one of the generation three (Gen3) CSP technologies that has potential for lowering the levelized cost of electricity produced by this solar thermal power systems. Commercially available ceramic particles, which are rated for high temperature applications up to 1200 °C, were selected for this study. This medium is commonly used as an energy carrier or heat transfer medium in Gen3 CSP research and development efforts [1]. Prior studies at the National Solar Thermal Test Facility (NSTTF) have investigated and evaluated various mass flow measurement methods, and a simple gravimetric temporal load measurement method was chosen as the best candidate for the research purpose [2]. This mass flow measurement method is a batch process and is not a viable solution for commercial-scale power generation applications based on cost, space, process control, and practical system integration factors. In-line and continuous particle mass flow measurement will play an integral role in efficient and cost effective Gen3 CSP particle technologies. Process parameters, including energy absorbed by the particles, receiver efficiency, temperature dependent flow phenomena, and general high temperature measurement reliability are all rely on repeatable and accurate measurement of particle mass flow under various operating conditions. Ceramic particles, like those used in this application, are not conventionally used as an energy carrier. A novel concept for continuous particle mass flow at a wide range of operating temperatures is currently under development and planned to be tested at the NSTTF, called the Particle In-LinE (PILE) mass flow sensor.

SolarPACES Conference ProceedingsVol. 2
Sandia National Laboratories (US)
U.S. Department of Energy, National Nuclear Security Administration, Sandia National Laboratories
Openalex Percentile: Top 82%
Cyclone Separators and Fluid Dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.