Code-based brittle capacity models for seismic assessment of pre-code RC buildings: comparison and consequences on retrofit

Abstract The existing Reinforced Concrete (RC) buildings stock is often characterized by a significant seismic vulnerability, due to the absence of capacity design principles, even in regions with high seismic hazard, such as Italy. Approximately 67% of existing RC buildings in Italy have been designed without considering seismic actions (GLD), resulting in very low transverse reinforcement amount in beams and, particularly, in columns. Additionally, beam-column joints typically totally lack stirrups. Consequently, shear failures under seismic actions are very likely for this pre-code building typology, often limiting their seismic capacity. However, the assessment of shear failures in beams/columns or joints varies significantly from code to code worldwide. The main goal of this work is to quantify the impact of different code-based brittle capacity models on the seismic capacity assessment and retrofit, focusing on GLD Italian pre-1970 RC buildings. This comparative analysis is carried out by first considering three current codes, emphasizing their, even significant, differences: European (EN 1998-3-1. 2005), Italian (D.M. 2018), and American (ASCE SEI/41 2017) standards. Then, shear capacity models prescribed by the current drafts of the next generation of Eurocodes are implemented and compared to the current models. The assessment includes: ( i ) a parametric comparison among models; ( ii ) the evaluation of case-study buildings capacity in their as-built condition and after shear strengthening interventions. The latter is performed on 3D “bare” models, due to the lack of practical guidance in most codes on modelling masonry infills.

Authors

Institutions

Publication Details

Journal
Bulletin of Earthquake Engineering
Published
2024-09-16
DOI
https://doi.org/10.1007/s10518-024-02016-6
Citations
2
Primary Topic
Seismic Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.52

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Code-based brittle capacity models for seismic assessment of pre-code RC buildings: comparison and consequences on retrofit

Santa Anna Scala, Gerardo Mario Verderame, Maria Teresa De Risi
2 citations
Bulletin of Earthquake Engineering
Seismic Performance and Analysis
0.52
article

Code-based brittle capacity models for seismic assessment of pre-code RC buildings: comparison and consequences on retrofit

Santa Anna Scala, Gerardo Mario Verderame, Maria Teresa De Risi
article en
2 citations

Abstract

Abstract The existing Reinforced Concrete (RC) buildings stock is often characterized by a significant seismic vulnerability, due to the absence of capacity design principles, even in regions with high seismic hazard, such as Italy. Approximately 67% of existing RC buildings in Italy have been designed without considering seismic actions (GLD), resulting in very low transverse reinforcement amount in beams and, particularly, in columns. Additionally, beam-column joints typically totally lack stirrups. Consequently, shear failures under seismic actions are very likely for this pre-code building typology, often limiting their seismic capacity. However, the assessment of shear failures in beams/columns or joints varies significantly from code to code worldwide. The main goal of this work is to quantify the impact of different code-based brittle capacity models on the seismic capacity assessment and retrofit, focusing on GLD Italian pre-1970 RC buildings. This comparative analysis is carried out by first considering three current codes, emphasizing their, even significant, differences: European (EN 1998-3-1. 2005), Italian (D.M. 2018), and American (ASCE SEI/41 2017) standards. Then, shear capacity models prescribed by the current drafts of the next generation of Eurocodes are implemented and compared to the current models. The assessment includes: ( i ) a parametric comparison among models; ( ii ) the evaluation of case-study buildings capacity in their as-built condition and after shear strengthening interventions. The latter is performed on 3D “bare” models, due to the lack of practical guidance in most codes on modelling masonry infills.

Bulletin of Earthquake EngineeringVol. 22(13)
University of Naples Federico II (IT)
Università degli Studi di Napoli Federico II, Dipartimento della Protezione Civile, Presidenza del Consiglio dei Ministri
Openalex Percentile: Top 36%
Seismic Performance and Analysis
0.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.