Evaluation of Radiopacity of Calcium Silicate-Based and Resin-Based Materials Using Direct Digital Radiography Along With an Aluminium Step Wedge

Background Radiopacity is a critical property for root canal sealers as it allows for the assessment of the material's placement and quality within the root canal system on radiographic images. The study aimed to evaluate the radiopacity of calcium silicate-based and resin-based materials using direct digital radiography, employing an aluminium step wedge according to American National Standards Institute/International Organization for Standardization (ANSI/ISO) standard protocols for testing the radiopacity of root canal sealers. This study seeks to determine the effectiveness of these materials in meeting the required standards for clinical use. Methodology The materials tested were AH Plus, Apexit Plus, Biodentine and MTA Fillapex in circular disc form and radiographed alongside the aluminium step wedge using direct digital radiography to determine the radiopacity using grey-pixel values. All the materials, viz., AH Plus, Apexit Plus, Biodentine and MTA Fillapex were found satisfactorily radiopaque and met the minimum radiopacity standard, that is, minimum 3mm of aluminium recommended by ANSI/American Dental Association (ADA) Specification No. 57. Results AH Plus exhibited the highest radiopacity with values of 222.54 mm Al Eq (isodensity) and 220.88 mm Al Eq (densitometric), significantly surpassing Apexit Plus, Fillapex and Biodentine (p < 0.001). Apexit Plus and Fillapex showed no significant difference between them (p = 0.238), but both were significantly higher than Biodentine (p < 0.001). Biodentine had the lowest radiopacity among all the sealers tested. Conclusion All the tested materials met the ANSI/ADA minimum radiopacity standard, demonstrating their suitability for clinical use. The materials varied in their levels of radiopacity, demonstrating that they are adequately visible on radiographic images for effective assessment in root canal treatments.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2024-09-23
DOI
https://doi.org/10.7759/cureus.70035
Citations
1
Primary Topic
Endodontics and Root Canal Treatments
Type
article
Field-Weighted Citation Impact
0.49
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Radiopacity of Calcium Silicate-Based and Resin-Based Materials Using Direct Digital Radiography Along With an Aluminium Step Wedge

Shubham Sandesh, Saleem Azhar, Sahil Dhingra, Vikas Singh et al.
1 citations
Cureus
Endodontics and Root Canal Treatments
0.49
article

Evaluation of Radiopacity of Calcium Silicate-Based and Resin-Based Materials Using Direct Digital Radiography Along With an Aluminium Step Wedge

Shubham Sandesh, Saleem Azhar, Sahil Dhingra, Vikas Singh, Sachin Yadav, Mohammad Salman Akhtar, Abhinay Agarwal
article en
1 citations

Abstract

Background Radiopacity is a critical property for root canal sealers as it allows for the assessment of the material's placement and quality within the root canal system on radiographic images. The study aimed to evaluate the radiopacity of calcium silicate-based and resin-based materials using direct digital radiography, employing an aluminium step wedge according to American National Standards Institute/International Organization for Standardization (ANSI/ISO) standard protocols for testing the radiopacity of root canal sealers. This study seeks to determine the effectiveness of these materials in meeting the required standards for clinical use. Methodology The materials tested were AH Plus, Apexit Plus, Biodentine and MTA Fillapex in circular disc form and radiographed alongside the aluminium step wedge using direct digital radiography to determine the radiopacity using grey-pixel values. All the materials, viz., AH Plus, Apexit Plus, Biodentine and MTA Fillapex were found satisfactorily radiopaque and met the minimum radiopacity standard, that is, minimum 3mm of aluminium recommended by ANSI/American Dental Association (ADA) Specification No. 57. Results AH Plus exhibited the highest radiopacity with values of 222.54 mm Al Eq (isodensity) and 220.88 mm Al Eq (densitometric), significantly surpassing Apexit Plus, Fillapex and Biodentine (p < 0.001). Apexit Plus and Fillapex showed no significant difference between them (p = 0.238), but both were significantly higher than Biodentine (p < 0.001). Biodentine had the lowest radiopacity among all the sealers tested. Conclusion All the tested materials met the ANSI/ADA minimum radiopacity standard, demonstrating their suitability for clinical use. The materials varied in their levels of radiopacity, demonstrating that they are adequately visible on radiographic images for effective assessment in root canal treatments.

CureusVol. 16(9)
Teerthanker Mahaveer University (IN), Manubhai Patel Dental College and Hospital (IN)
Openalex Percentile: Top 35%
Endodontics and Root Canal Treatments
0.49
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.