Hydrogel Capacitors Based on MoS2 Nanosheets and Applications in Glucose Monitoring

Non-invasive/minimally invasive continuous monitoring of blood glucose and blood glucose administration have a high impact on chronic disease management in diabetic patients, but the existing technology is yet to achieve the above two purposes at the same time. Therefore, this study proposes a microfluidic microneedle patch based on 3D printing technology and an integrated control system design for blood glucose measurement, and a drug delivery control circuit based on a 555 chip. The proposed method provides an improved preparation of a PVA-PEG-MoS<sub>2</sub> nanosheet hydrogel, making use of its dielectric properties to fabricate a microcapacitor and then embedding it in a microfluidic chip. When MoS<sub>2</sub> nanosheets react with interstitial liquid glucose (and during the calibration process), the permittivity of the hydrogel is changed, resulting in changes in the capacitance of the capacitor. By converting the capacitance change into the square-wave period change in the output of the 555 chip with the control circuit design accordingly, the minimally invasive continuous measurement of blood glucose and the controlled release of hypoglycemic drugs are realized. In this study, the cross-linking structure of MoS<sub>2</sub> nanosheets in hydrogel was examined using infrared spectroscopy and scanning electron microscopy (SEM) methods. Moreover, the critical doping mass fraction of MoS<sub>2</sub> nanosheets was determined to be 2% via the measurement of the dielectric constant. Meanwhile, the circuit design and the relationship between the pulse cycle and glucose concentration is validated. The results show that, compared with capacitors in series, the microcapacitors embedded in microfluidic channels can be connected in parallel to obtain better linearized blood glucose measurement results.

Authors

Institutions

Publication Details

Journal
Molecules
Published
2024-09-16
DOI
https://doi.org/10.3390/molecules29184401
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hydrogel Capacitors Based on MoS2 Nanosheets and Applications in Glucose Monitoring

Yang Zhang, Hui Lin, Jinwen Zhang, Yizhi Wang et al.
Molecules
Electrochemical sensors and biosensors
article

Hydrogel Capacitors Based on MoS2 Nanosheets and Applications in Glucose Monitoring

Yang Zhang, Hui Lin, Jinwen Zhang, Yizhi Wang, Yusen Zhang, Bing Wang
article en

Abstract

Non-invasive/minimally invasive continuous monitoring of blood glucose and blood glucose administration have a high impact on chronic disease management in diabetic patients, but the existing technology is yet to achieve the above two purposes at the same time. Therefore, this study proposes a microfluidic microneedle patch based on 3D printing technology and an integrated control system design for blood glucose measurement, and a drug delivery control circuit based on a 555 chip. The proposed method provides an improved preparation of a PVA-PEG-MoS<sub>2</sub> nanosheet hydrogel, making use of its dielectric properties to fabricate a microcapacitor and then embedding it in a microfluidic chip. When MoS<sub>2</sub> nanosheets react with interstitial liquid glucose (and during the calibration process), the permittivity of the hydrogel is changed, resulting in changes in the capacitance of the capacitor. By converting the capacitance change into the square-wave period change in the output of the 555 chip with the control circuit design accordingly, the minimally invasive continuous measurement of blood glucose and the controlled release of hypoglycemic drugs are realized. In this study, the cross-linking structure of MoS<sub>2</sub> nanosheets in hydrogel was examined using infrared spectroscopy and scanning electron microscopy (SEM) methods. Moreover, the critical doping mass fraction of MoS<sub>2</sub> nanosheets was determined to be 2% via the measurement of the dielectric constant. Meanwhile, the circuit design and the relationship between the pulse cycle and glucose concentration is validated. The results show that, compared with capacitors in series, the microcapacitors embedded in microfluidic channels can be connected in parallel to obtain better linearized blood glucose measurement results.

MoleculesVol. 29(18)
Minjiang University (CN), Ningde Normal University (CN), Jinling Institute of Technology (CN)
Jiangsu Academy of Agricultural Sciences, National Natural Science Foundation of China, Government of Jiangsu Province, Minjiang University, Jinling Institute of Technology
Good health and well-being
Openalex Percentile: Top 86%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.