Localization Method for Insulation Degradation Area of the Metro Rail-to-Ground Based on Monitor Information

Since rail-to-ground insulation decreases, large-level direct currents (DCs) leak from railways and form metro stray currents, corroding the buried metal. To locate the rail-to-ground insulation deterioration area, a location method is proposed based on parameter identification methods and the monitored information including the station rail potentials, currents at the traction power substations (TPSs), and train traction currents and train positions. According to the monitoring information of two adjacent TPSs, the section location model of the metro line is proposed, in which the rail-to-ground conductances of the test section are equivalent to the lumped parameters. Using the rail resistivity and traction currents as the known information, the rail-to-ground conductances are calculated with the least square method (LSM). The rail-to-ground insulation deterioration sections are identified by comparing the calculated conductances with thresholds determined by the standard requirements and section lengths. Then, according to the section location results, a detailed location model of the degradation section is proposed, considering the location distance accuracy. Using the genetic algorithm (GA) to calculate the rail-to-ground conductances, degradation positions are located by comparing the threshold calculated with the standard requirements and location distance accuracy. The location method is verified by comparing the calculation results under different degradation conditions. Moreover, the applications of the proposed method to different degradation lengths and different numbers of degradation sections are analyzed. The results show that the proposed method can locate rail-to-ground insulation deterioration areas.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2024-09-16
DOI
https://doi.org/10.3390/electronics13183678
Citations
3
Primary Topic
Railway Systems and Energy Efficiency
Type
article
Field-Weighted Citation Impact
1.05

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Localization Method for Insulation Degradation Area of the Metro Rail-to-Ground Based on Monitor Information

Aimin Wang, Yu Li, Guangxu Pan, Wenxuan Yang
3 citations
Electronics
Railway Systems and Energy Efficiency
1.05
article

Localization Method for Insulation Degradation Area of the Metro Rail-to-Ground Based on Monitor Information

Aimin Wang, Yu Li, Guangxu Pan, Wenxuan Yang
article en
3 citations

Abstract

Since rail-to-ground insulation decreases, large-level direct currents (DCs) leak from railways and form metro stray currents, corroding the buried metal. To locate the rail-to-ground insulation deterioration area, a location method is proposed based on parameter identification methods and the monitored information including the station rail potentials, currents at the traction power substations (TPSs), and train traction currents and train positions. According to the monitoring information of two adjacent TPSs, the section location model of the metro line is proposed, in which the rail-to-ground conductances of the test section are equivalent to the lumped parameters. Using the rail resistivity and traction currents as the known information, the rail-to-ground conductances are calculated with the least square method (LSM). The rail-to-ground insulation deterioration sections are identified by comparing the calculated conductances with thresholds determined by the standard requirements and section lengths. Then, according to the section location results, a detailed location model of the degradation section is proposed, considering the location distance accuracy. Using the genetic algorithm (GA) to calculate the rail-to-ground conductances, degradation positions are located by comparing the threshold calculated with the standard requirements and location distance accuracy. The location method is verified by comparing the calculation results under different degradation conditions. Moreover, the applications of the proposed method to different degradation lengths and different numbers of degradation sections are analyzed. The results show that the proposed method can locate rail-to-ground insulation deterioration areas.

ElectronicsVol. 13(18)
Xihua University (CN)
National Natural Science Foundation of China, Chengdu Science and Technology Program
Openalex Percentile: Top 20%
Railway Systems and Energy Efficiency
1.05
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Localization Method for Insulation Degradation Area of the Metro Rail-to-Ground Based on Monitor Information — Aimin Wang, Yu Li, et al. · Electronics (2024) | TGRS Research Map | TGRS