DiffCNBP: Lightweight Diffusion Model for IoMT-Based Continuous Cuffless Blood Pressure Waveform Monitoring Using PPG

Continuous monitoring of blood pressure (BP) waveform is challenging in clinical applications due to the invasive nature of traditional techniques. As a result, there is a growing focus on the estimation of continuous BP waveforms from photoplethysmography (PPG) signals obtained through affordable wearable Internet of Medical Things (IoMT) devices. To address this demand, we introduce diffusion for continuous noninvasive BP (DiffCNBP), a lightweight model that employs a joint optimization approach incorporating sequence learning, diffusion modeling, and conditional embedding. The sequence learning module comprises stacked Transformer encoders to capture the temporal information of the PPG signals. These dynamically related features are then fed into a lightweight diffusion module based on structured state-space sequence encoders to learn detailed variation features associated with vascular dynamics. Additionally, the conditional embedding module introduces constraints to incorporate physiologically specific prior information for model estimation, thereby enhancing the fidelity of the estimated BP waveform. Our proposed method was validated using subject-wise fivefold cross-validation on a multisource database of 1415 subjects. This database included data from intensive care unit IoMT applications, where finger-based PPG sensors were employed alongside invasive BP sensors. Experimental results demonstrate that DiffCNBP outperforms other state-of-the-art methods with an average root-mean-square error of 4.36 mmHg for waveform estimation. The mean error ± standard deviation error of systolic and diastolic BP was <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$0.67~\pm ~4.29$ </tex-math></inline-formula> mmHg and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$0.37~\pm ~2.46$ </tex-math></inline-formula> mmHg, respectively, meeting the clinical standards. Furthermore, we demonstrated the robust long-term trend-tracking ability of DiffCNBP on resource-constrained devices, indicating its potential IoMT deployment in clinical settings.

Authors

Institutions

Publication Details

Journal
IEEE Internet of Things Journal
Published
2024-09-16
DOI
https://doi.org/10.1109/jiot.2024.3460382
Citations
7
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
1.29

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DiffCNBP: Lightweight Diffusion Model for IoMT-Based Continuous Cuffless Blood Pressure Waveform Monitoring Using PPG

Lishuang Guo, Chenbin Ma, Guanglei Zhang, Haonan Zhang et al.
7 citations
IEEE Internet of Things Journal
Non-Invasive Vital Sign Monitoring
1.29
article

DiffCNBP: Lightweight Diffusion Model for IoMT-Based Continuous Cuffless Blood Pressure Waveform Monitoring Using PPG

Lishuang Guo, Chenbin Ma, Guanglei Zhang, Haonan Zhang, Zhenchang Liu
article en
7 citations

Abstract

Continuous monitoring of blood pressure (BP) waveform is challenging in clinical applications due to the invasive nature of traditional techniques. As a result, there is a growing focus on the estimation of continuous BP waveforms from photoplethysmography (PPG) signals obtained through affordable wearable Internet of Medical Things (IoMT) devices. To address this demand, we introduce diffusion for continuous noninvasive BP (DiffCNBP), a lightweight model that employs a joint optimization approach incorporating sequence learning, diffusion modeling, and conditional embedding. The sequence learning module comprises stacked Transformer encoders to capture the temporal information of the PPG signals. These dynamically related features are then fed into a lightweight diffusion module based on structured state-space sequence encoders to learn detailed variation features associated with vascular dynamics. Additionally, the conditional embedding module introduces constraints to incorporate physiologically specific prior information for model estimation, thereby enhancing the fidelity of the estimated BP waveform. Our proposed method was validated using subject-wise fivefold cross-validation on a multisource database of 1415 subjects. This database included data from intensive care unit IoMT applications, where finger-based PPG sensors were employed alongside invasive BP sensors. Experimental results demonstrate that DiffCNBP outperforms other state-of-the-art methods with an average root-mean-square error of 4.36 mmHg for waveform estimation. The mean error ± standard deviation error of systolic and diastolic BP was <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$0.67~\pm ~4.29$ </tex-math></inline-formula> mmHg and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$0.37~\pm ~2.46$ </tex-math></inline-formula> mmHg, respectively, meeting the clinical standards. Furthermore, we demonstrated the robust long-term trend-tracking ability of DiffCNBP on resource-constrained devices, indicating its potential IoMT deployment in clinical settings.

IEEE Internet of Things JournalVol. 12(1)
Beihang University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 22%
Non-Invasive Vital Sign Monitoring
1.29
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.