A Fluorescence Enhancement Sensor Based on Silver Nanoclusters Protected by Rich-G-DNA for ATP Detection

In this study, a turn-on fluorescence sensor for the detection of adenosine 5'-triphosphate (ATP) was developed and tested using ATP-DNA2-Ag NCs. The results showed that the fluorescence of ATP-DNA2-Ag NCs was significantly enhanced with the addition of ATP. The fluorescence enhancement was a result of the specific binding activity of the ATP aptamer and ATP, which caused G-rich sequences to approach the dark DNA-Ag NCs, owing to the alteration in ATP aptamer conformation. The proposed sensor demonstrated a good linear range of 18-42 mM and a limit of detection (LOD) of 2.8 μM. The sensor's features include sensitivity, selectivity, and simple operation. In addition, the proposed sensor successfully measured ATP in 100-fold diluted fetal bovine serum.

Authors

Institutions

Publication Details

Journal
Molecules
Published
2024-09-21
DOI
https://doi.org/10.3390/molecules29184490
Citations
1
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.23

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Fluorescence Enhancement Sensor Based on Silver Nanoclusters Protected by Rich-G-DNA for ATP Detection

Baozhu Zhang, Yuxia Li, Zeting Meng, Jingxuan Ren
1 citations
Molecules
Advanced biosensing and bioanalysis techniques
0.23
article

A Fluorescence Enhancement Sensor Based on Silver Nanoclusters Protected by Rich-G-DNA for ATP Detection

Baozhu Zhang, Yuxia Li, Zeting Meng, Jingxuan Ren
article en
1 citations

Abstract

In this study, a turn-on fluorescence sensor for the detection of adenosine 5'-triphosphate (ATP) was developed and tested using ATP-DNA2-Ag NCs. The results showed that the fluorescence of ATP-DNA2-Ag NCs was significantly enhanced with the addition of ATP. The fluorescence enhancement was a result of the specific binding activity of the ATP aptamer and ATP, which caused G-rich sequences to approach the dark DNA-Ag NCs, owing to the alteration in ATP aptamer conformation. The proposed sensor demonstrated a good linear range of 18-42 mM and a limit of detection (LOD) of 2.8 μM. The sensor's features include sensitivity, selectivity, and simple operation. In addition, the proposed sensor successfully measured ATP in 100-fold diluted fetal bovine serum.

MoleculesVol. 29(18)
Jinzhong University (CN)
Jinzhong University
Openalex Percentile: Top 42%
Advanced biosensing and bioanalysis techniques
0.23
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.