Calibration Methods for Large-Scale and High-Precision Globalization of Local Point Cloud Data Based on iGPS

The point cloud is one of the measurement results of local measurement and is widely used because of its high measurement accuracy, high data density, and low environmental impact. However, since point cloud data from a single measurement are generally small in spatial extent, it is necessary to accurately globalize the local point cloud to measure large components. In this paper, the method of using an iGPS (indoor Global Positioning System) as an external measurement device to realize high-accuracy globalization of local point cloud data is proposed. Two calibration models are also discussed for different application scenarios. Verification experiments prove that the average calibration errors of these two calibration models are 0.12 mm and 0.17 mm, respectively. The proposed method can maintain calibration precision in a large spatial range (about 10 m × 10 m × 5 m), which is of high value for engineering applications.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2024-09-21
DOI
https://doi.org/10.3390/s24186114
Citations
1
Primary Topic
Advanced Measurement and Metrology Techniques
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calibration Methods for Large-Scale and High-Precision Globalization of Local Point Cloud Data Based on iGPS

Thomas Dunker, Zhigang Xu, Rui Han, Erik Trostmann
1 citations
Sensors
Advanced Measurement and Metrology Techniques
0.21
article

Calibration Methods for Large-Scale and High-Precision Globalization of Local Point Cloud Data Based on iGPS

Thomas Dunker, Zhigang Xu, Rui Han, Erik Trostmann
article en
1 citations

Abstract

The point cloud is one of the measurement results of local measurement and is widely used because of its high measurement accuracy, high data density, and low environmental impact. However, since point cloud data from a single measurement are generally small in spatial extent, it is necessary to accurately globalize the local point cloud to measure large components. In this paper, the method of using an iGPS (indoor Global Positioning System) as an external measurement device to realize high-accuracy globalization of local point cloud data is proposed. Two calibration models are also discussed for different application scenarios. Verification experiments prove that the average calibration errors of these two calibration models are 0.12 mm and 0.17 mm, respectively. The proposed method can maintain calibration precision in a large spatial range (about 10 m × 10 m × 5 m), which is of high value for engineering applications.

SensorsVol. 24(18)
Shenyang Institute of Automation (CN), Chinese Academy of Sciences (CN), Fraunhofer Institute for Factory Operation and Automation (DE), University of Chinese Academy of Sciences (CN)
Openalex Percentile: Top 52%
Advanced Measurement and Metrology Techniques
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.