Improvement of the energy resolution and non-proportional light response of CsI:Tl to gamma radiation using dynamic integration times

Abstract The analysis of the light response of thallium-doped cesium iodide to gamma radiation was performed on single scintillation waveforms recorded using a digital oscilloscope. As an alternative to classical pulse processing procedures, the use of dynamic integration times instead of fixed shaping/integration times was demonstrated. The dynamic integration time, changeable with the amplitudes of the CsI:Tl scintillation pulses, allowed to optimise the light collection with simultaneous minimization of a noise contribution. It was shown that for low-energy γ -rays (22 keV–60 keV), the scintillation pulses should be integrated using shorter integration times (approximately 7 μ s–14 μs), whereas for higher energies (662 keV–835 keV), the best energy resolution was achieved with integration times of about 28 μ s–30 μ s. The approach also allowed for the registration of more proportional CsI:Tl light responses to deposited X and gamma radiation in the energy range of 22 keV–835 keV.

Authors

Institutions

Publication Details

Journal
Journal of Instrumentation
Published
2024-09-01
DOI
https://doi.org/10.1088/1748-0221/19/09/p09029
Citations
1
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.61
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improvement of the energy resolution and non-proportional light response of CsI:Tl to gamma radiation using dynamic integration times

A. Gektin, A. Syntfeld-Każuch, Z. Mianowska, S. Mianowski et al.
1 citations
Journal of Instrumentation
Radiation Detection and Scintillator Technologies
0.61
article

Improvement of the energy resolution and non-proportional light response of CsI:Tl to gamma radiation using dynamic integration times

A. Gektin, A. Syntfeld-Każuch, Z. Mianowska, S. Mianowski, R. Alberts
article en
1 citations

Abstract

Abstract The analysis of the light response of thallium-doped cesium iodide to gamma radiation was performed on single scintillation waveforms recorded using a digital oscilloscope. As an alternative to classical pulse processing procedures, the use of dynamic integration times instead of fixed shaping/integration times was demonstrated. The dynamic integration time, changeable with the amplitudes of the CsI:Tl scintillation pulses, allowed to optimise the light collection with simultaneous minimization of a noise contribution. It was shown that for low-energy γ -rays (22 keV–60 keV), the scintillation pulses should be integrated using shorter integration times (approximately 7 μ s–14 μs), whereas for higher energies (662 keV–835 keV), the best energy resolution was achieved with integration times of about 28 μ s–30 μ s. The approach also allowed for the registration of more proportional CsI:Tl light responses to deposited X and gamma radiation in the energy range of 22 keV–835 keV.

Journal of InstrumentationVol. 19(09)
National Academy of Sciences of Ukraine (UA), Diamond Light Source (GB), National Centre for Nuclear Research (PL), Institute for Scintillation Materials (UA)
Openalex Percentile: Top 31%
Radiation Detection and Scintillator Technologies
0.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.