Performance Evaluation of Distance Relay Operation in Distribution Systems with Integrated Distributed Energy Resources

This article presents the evaluation of the performance of the distance relay (ANSI function 21) when integrating Distributed Energy Resources (DERs) in a Local Distribution System (LDS). The aim is to understand the impacts of and the necessary modifications required in the operation of distance relays, considering different levels of DER aggregation, and identifying any threshold levels before issues arise. To achieve this, first, a comprehensive review was carried out to analyze the impacts generated in the protection systems. Second, by using the DigSilent Power Factory software, the implementation of the distance relay using a IEEE 13 Node Test Feeder was validated. The aggregation of the three fundamental types of DG, synchronous machines, solar panels, and wind turbines, was evaluated. The threshold at which distributed generation power injection begins to compromise distance protection performance was identified. This study compares the outcomes of using mho and quadrilateral protection schemes.

Authors

Institutions

Publication Details

Journal
Energies
Published
2024-09-23
DOI
https://doi.org/10.3390/en17184735
Citations
5
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
1.64

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Evaluation of Distance Relay Operation in Distribution Systems with Integrated Distributed Energy Resources

Juan C. Vásquez, Eduardo Gómez-Luna, David R. Garibello-Narváez
5 citations
Energies
Power Systems Fault Detection
1.64
article

Performance Evaluation of Distance Relay Operation in Distribution Systems with Integrated Distributed Energy Resources

Juan C. Vásquez, Eduardo Gómez-Luna, David R. Garibello-Narváez
article en
5 citations

Abstract

This article presents the evaluation of the performance of the distance relay (ANSI function 21) when integrating Distributed Energy Resources (DERs) in a Local Distribution System (LDS). The aim is to understand the impacts of and the necessary modifications required in the operation of distance relays, considering different levels of DER aggregation, and identifying any threshold levels before issues arise. To achieve this, first, a comprehensive review was carried out to analyze the impacts generated in the protection systems. Second, by using the DigSilent Power Factory software, the implementation of the distance relay using a IEEE 13 Node Test Feeder was validated. The aggregation of the three fundamental types of DG, synchronous machines, solar panels, and wind turbines, was evaluated. The threshold at which distributed generation power injection begins to compromise distance protection performance was identified. This study compares the outcomes of using mho and quadrilateral protection schemes.

EnergiesVol. 17(18)
Aalborg University (DK), Universidad del Valle (CO)
Villum Fonden
Affordable and clean energy
Openalex Percentile: Top 16%
Power Systems Fault Detection
1.64
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.