Detection of Broken Bars in Induction Motors Operating with Closed-Loop Speed Control

Rotor bar breakage in induction motors is often detected by analysing the signatures in the stator current. However, due to the alteration of the current spectrum, traditional methods may fail when inverter-fed motors operate with closed-loop control using a cascade structure to regulate the speed. In this paper, the potential of zero-sequence voltage analysis to detect this fault is investigated, and a new index to quantify the severity of the fault based on this signal is proposed. Signals from motors operating under different control strategies and signals from motors powered from the mains are considered to verify the robustness of the proposed fault severity index. As a result, in all the analysed conditions the value of the proposed index for the healthy motor is found to be approximately 0.010, while for the faulty machine it is between 0.110 and 0.252.

Authors

Institutions

Publication Details

Journal
Machines
Published
2024-09-21
DOI
https://doi.org/10.3390/machines12090662
Citations
8
Primary Topic
Machine Fault Diagnosis Techniques
Type
article
Field-Weighted Citation Impact
2.63
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detection of Broken Bars in Induction Motors Operating with Closed-Loop Speed Control

Lorenzo Mantione, F. Muzio, Tomas Garcia-Calva, Lucia Frosini et al.
8 citations
Machines
Machine Fault Diagnosis Techniques
2.63
article

Detection of Broken Bars in Induction Motors Operating with Closed-Loop Speed Control

Lorenzo Mantione, F. Muzio, Tomas Garcia-Calva, Lucia Frosini, Daniel Moríñigo-Sotelo
article en
8 citations

Abstract

Rotor bar breakage in induction motors is often detected by analysing the signatures in the stator current. However, due to the alteration of the current spectrum, traditional methods may fail when inverter-fed motors operate with closed-loop control using a cascade structure to regulate the speed. In this paper, the potential of zero-sequence voltage analysis to detect this fault is investigated, and a new index to quantify the severity of the fault based on this signal is proposed. Signals from motors operating under different control strategies and signals from motors powered from the mains are considered to verify the robustness of the proposed fault severity index. As a result, in all the analysed conditions the value of the proposed index for the healthy motor is found to be approximately 0.010, while for the faulty machine it is between 0.110 and 0.252.

MachinesVol. 12(9)
Universidad de Valladolid (ES), University of Pavia (IT)
Affordable and clean energy
Openalex Percentile: Top 10%
Machine Fault Diagnosis Techniques
2.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Detection of Broken Bars in Induction Motors Operating with Closed-Loop Speed Control — Lorenzo Mantione, F. Muzio, et al. · Machines (2024) | TGRS Research Map | TGRS