Mechanically Aligned Second-Generation Medial Pivot Primary Total Knee Arthroplasty Does Not Reproduce Normal Knee Biomechanics: A Gait Analysis Study

<b>Background:</b> This study aimed to evaluate post-operative lower limb function following second-generation mechanically aligned medial pivot (MP) TKA implantation. Standard gait analysis was performed to collect kinematic and kinetic data, which were then compared with physiological data from the literature obtained using the same evaluation methodology as the present study. The hypothesis was that this TKA would not fully restore normal knee and adjacent joint motion during walking. <b>Methods:</b> Our cohort comprised 15 patients consecutively enrolled from September 2019 to December 2022 who underwent primary TKA with the second-generation MP Evolution Knee System (MicroPort Orthopaedics Inc., Arlington, TN, USA). Pre-operatively and 6 months post-surgery, gait analysis during level walking was performed on all patients, as well as clinical evaluations using the Knee Society Score (KSS), the Knee Injury and Osteoarthritis Outcome Score (KOOS), and the Visual Analogue Scale (VAS). <b>Results:</b> The clinical scores improved significantly (<i>p</i> < 0.001) after surgery (pre-/post-operative KSS functional, KSS clinical, VAS, and KOOS: 51.7 ± 17.3/84 ± 18.4, 45.3 ± 16.2/74.1 ± 12.6, 6.9 ± 1.8/2.0 ± 1.9, and 33.9 ± 11.8/69.1 ± 16.5, respectively). The statistical parametric mapping (SPM) analysis between the post-operative and reference control data revealed significant differences in the initial and final 20% of the gait cycle for the rotation of the knee in the frontal and transverse planes and for the rotation of the ankle in the sagittal plane. <b>Conclusions:</b> This study shows that new-generation MP TKA with mechanical alignment does not fully restore normal gait biomechanics, particularly in knee rotational movements, indicating a need for improved surgical techniques and prosthetic designs.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2024-09-22
DOI
https://doi.org/10.3390/jcm13185623
Citations
2
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
1.15
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mechanically Aligned Second-Generation Medial Pivot Primary Total Knee Arthroplasty Does Not Reproduce Normal Knee Biomechanics: A Gait Analysis Study

Maurizio Ortolani, Stefano Zaffagnini, Alberto Leardini, Giulio Maria Marcheggiani Muccioli et al.
2 citations
Journal of Clinical Medicine
Total Knee Arthroplasty Outcomes
1.15
article

Mechanically Aligned Second-Generation Medial Pivot Primary Total Knee Arthroplasty Does Not Reproduce Normal Knee Biomechanics: A Gait Analysis Study

Maurizio Ortolani, Stefano Zaffagnini, Alberto Leardini, Giulio Maria Marcheggiani Muccioli, Giada Lullini, Eugenio Cammisa, Matteo La Verde, Claudio Belvedere, Nicoletta Sileoni, Domenico Alesi, Alberto Fogacci
article en
2 citations

Abstract

<b>Background:</b> This study aimed to evaluate post-operative lower limb function following second-generation mechanically aligned medial pivot (MP) TKA implantation. Standard gait analysis was performed to collect kinematic and kinetic data, which were then compared with physiological data from the literature obtained using the same evaluation methodology as the present study. The hypothesis was that this TKA would not fully restore normal knee and adjacent joint motion during walking. <b>Methods:</b> Our cohort comprised 15 patients consecutively enrolled from September 2019 to December 2022 who underwent primary TKA with the second-generation MP Evolution Knee System (MicroPort Orthopaedics Inc., Arlington, TN, USA). Pre-operatively and 6 months post-surgery, gait analysis during level walking was performed on all patients, as well as clinical evaluations using the Knee Society Score (KSS), the Knee Injury and Osteoarthritis Outcome Score (KOOS), and the Visual Analogue Scale (VAS). <b>Results:</b> The clinical scores improved significantly (<i>p</i> < 0.001) after surgery (pre-/post-operative KSS functional, KSS clinical, VAS, and KOOS: 51.7 ± 17.3/84 ± 18.4, 45.3 ± 16.2/74.1 ± 12.6, 6.9 ± 1.8/2.0 ± 1.9, and 33.9 ± 11.8/69.1 ± 16.5, respectively). The statistical parametric mapping (SPM) analysis between the post-operative and reference control data revealed significant differences in the initial and final 20% of the gait cycle for the rotation of the knee in the frontal and transverse planes and for the rotation of the ankle in the sagittal plane. <b>Conclusions:</b> This study shows that new-generation MP TKA with mechanical alignment does not fully restore normal gait biomechanics, particularly in knee rotational movements, indicating a need for improved surgical techniques and prosthetic designs.

Journal of Clinical MedicineVol. 13(18)
Istituto Ortopedico Rizzoli (IT), Istituto delle Scienze Neurologiche di Bologna (IT), University of Bologna (IT)
Good health and well-being
Openalex Percentile: Top 20%
Total Knee Arthroplasty Outcomes
1.15
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.