Study and Experimental Verification on Anti-Disturbance Control Strategy for Electro-Mechanical Servo Systems

With technological advances and industrial upgrading, electro-mechanical actuators (EMAs) have gradually replaced traditional hydraulic actuation systems. During operation, force servo systems inevitably suffer from external force or position disturbances, thus affecting the output performance of the system. Therefore, it is of significant engineering application value to develop EMA anti-disturbance control strategies that exhibit strong robustness and are more easily applicable to engineering practice. In this study, an open-loop transfer function of the system with command signals and disturbance signals as inputs was established based on the nonlinear mathematical models built for the core components of EMAs. To overcome the impact of external position disturbances on the motion performance of the force servo system, a proportional integral derivative (PID) controller was introduced and a high-order transfer function associated with various parameters such as speed and acceleration was derived and obtained as feedforward compensation based on the mathematical model. By incorporating a three-loop PID controller, the impact of external disturbance forces on the motion performance of the position servo system was overcome and the tracking accuracy of the system was also improved. Finally, simulation models were built using AMESim software (AMESim 2020, LMS Imagine.Lab, Roanne, France) and a dual-channel EMA performance testing system was developed. Simulation and test results indicated that both anti-disturbance control methods exhibited strong robustness and excellent anti-disturbance performance, with the control accuracy and dynamic performance almost unaffected by disturbances. This verified the correctness of the single-channel EMA anti-disturbance control strategy and the usability of the simulation model.

Authors

Institutions

Publication Details

Journal
Actuators
Published
2024-09-23
DOI
https://doi.org/10.3390/act13090377
Primary Topic
Hydraulic and Pneumatic Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study and Experimental Verification on Anti-Disturbance Control Strategy for Electro-Mechanical Servo Systems

Shicheng Zheng, Deyi Wang, Yunjie Yang, Jihong Zhu et al.
Actuators
Hydraulic and Pneumatic Systems
article

Study and Experimental Verification on Anti-Disturbance Control Strategy for Electro-Mechanical Servo Systems

Shicheng Zheng, Deyi Wang, Yunjie Yang, Jihong Zhu, Jingkun Wei
article en

Abstract

With technological advances and industrial upgrading, electro-mechanical actuators (EMAs) have gradually replaced traditional hydraulic actuation systems. During operation, force servo systems inevitably suffer from external force or position disturbances, thus affecting the output performance of the system. Therefore, it is of significant engineering application value to develop EMA anti-disturbance control strategies that exhibit strong robustness and are more easily applicable to engineering practice. In this study, an open-loop transfer function of the system with command signals and disturbance signals as inputs was established based on the nonlinear mathematical models built for the core components of EMAs. To overcome the impact of external position disturbances on the motion performance of the force servo system, a proportional integral derivative (PID) controller was introduced and a high-order transfer function associated with various parameters such as speed and acceleration was derived and obtained as feedforward compensation based on the mathematical model. By incorporating a three-loop PID controller, the impact of external disturbance forces on the motion performance of the position servo system was overcome and the tracking accuracy of the system was also improved. Finally, simulation models were built using AMESim software (AMESim 2020, LMS Imagine.Lab, Roanne, France) and a dual-channel EMA performance testing system was developed. Simulation and test results indicated that both anti-disturbance control methods exhibited strong robustness and excellent anti-disturbance performance, with the control accuracy and dynamic performance almost unaffected by disturbances. This verified the correctness of the single-channel EMA anti-disturbance control strategy and the usability of the simulation model.

ActuatorsVol. 13(9)
Beihang University (CN), Tsinghua University (CN)
Openalex Percentile: Top 84%
Hydraulic and Pneumatic Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.