Methodology study for determining the half-value layer using the Monte Carlo code PHITS

For most purposes, the quality of a beam can be specified in terms of the half-value layer (HVL), which is the thickness of material required to reduce the air kerma to half, at one meter from the source, from a unidirectional beam of infinitesimal width. Just like many other radiological quantities of interest, the HVL can be estimated via simulations employing the Monte Carlo Method (MCM). Among the variety of MCM based codes available, the Particles and Heavy Ions Transport Code System (PHITS) was the one adopted in this study. Primarily, simulations were conducted to determine the X-ray spectra resulting from the interaction of electron beams with different energies with a tungsten anode. Each of these spectra was then defined as a probability distribution for the photon source energies in a second round of simulations, where it was possible to estimate the X-ray beam qualities as specified by the reference literature. At this stage, it was possible to estimate the mean energy of the beam and the conversion coefficient for air kerma per unit fluence for each of the qualities. The results obtained in this phase were used to define the sources for other groups of simulations, where the air kerma was quantified for each source configuration, for different thicknesses of an aluminum metallic attenuator, which was also done with spectra for the same X-ray beam qualities obtained from a reference catalog. Curve fitting on the scatter of kerma points as a function of attenuation allowed the estimation of the HVL. The results obtained are consistent with the values described in the literature and demonstrate the efficiency of the developed methodology, as well as the use of the code in the evaluated energy range for X-rays.

Authors

Institutions

Publication Details

Journal
Brazilian Journal of Radiation Sciences
Published
2024-09-23
DOI
https://doi.org/10.15392/2319-0612.2024.2483
Primary Topic
Nuclear Physics and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Methodology study for determining the half-value layer using the Monte Carlo code PHITS

Marco Aurélio de Sousa Lacerda, Ronald Soares
Brazilian Journal of Radiation Sciences
Nuclear Physics and Applications
article

Methodology study for determining the half-value layer using the Monte Carlo code PHITS

Marco Aurélio de Sousa Lacerda, Ronald Soares
article en

Abstract

For most purposes, the quality of a beam can be specified in terms of the half-value layer (HVL), which is the thickness of material required to reduce the air kerma to half, at one meter from the source, from a unidirectional beam of infinitesimal width. Just like many other radiological quantities of interest, the HVL can be estimated via simulations employing the Monte Carlo Method (MCM). Among the variety of MCM based codes available, the Particles and Heavy Ions Transport Code System (PHITS) was the one adopted in this study. Primarily, simulations were conducted to determine the X-ray spectra resulting from the interaction of electron beams with different energies with a tungsten anode. Each of these spectra was then defined as a probability distribution for the photon source energies in a second round of simulations, where it was possible to estimate the X-ray beam qualities as specified by the reference literature. At this stage, it was possible to estimate the mean energy of the beam and the conversion coefficient for air kerma per unit fluence for each of the qualities. The results obtained in this phase were used to define the sources for other groups of simulations, where the air kerma was quantified for each source configuration, for different thicknesses of an aluminum metallic attenuator, which was also done with spectra for the same X-ray beam qualities obtained from a reference catalog. Curve fitting on the scatter of kerma points as a function of attenuation allowed the estimation of the HVL. The results obtained are consistent with the values described in the literature and demonstrate the efficiency of the developed methodology, as well as the use of the code in the evaluated energy range for X-rays.

Brazilian Journal of Radiation SciencesVol. 12(3)
Universidade Federal de Minas Gerais (BR), Centro de Desenvolvimento da Tecnologia Nuclear (BR)
Conselho Nacional de Desenvolvimento Científico e Tecnológico
Openalex Percentile: Top 79%
Nuclear Physics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.