Relevance of Tibial Fixation during Tibiotarsal Joint Traction: Descriptive Cross-Sectional Study

<b>Background:</b> The effect of tibial fixation on the movement of the talus during the tibiotarsal axial traction technique (TATT) is unknown. The aim was to evaluate the effect on the tibiotarsus when applying three different intensities of TATT force with or without tibial fixation in healthy subjects, and to assess the reliability of detecting the different forces applied. Also, the discomfort generated during the technique would be analysed. <b>Methods:</b> A cross-sectional study was conducted in thirty lower limbs. Three magnitudes of TATT force in an open-packed position were applied in tibial fixation and non-fixation conditions. The axial traction movement was measured by ultrasound, and the magnitudes of the force applied during low-medium and high TATT force were recorded in both conditions. Patients were asked about the level of discomfort perceived during the technique. <b>Results:</b> The most significant distance increase (mm) was observed in the tibial fixation condition at all magnitudes of the TATT (F = 102.693, <i>p</i> < 0.001). The discomfort sensation (numeric rating scale, "NRS") was higher in the non-fixation condition (<i>p</i> > 0.05). The application of the technique showed good reliability (>0.75 ICC) for the detection of the applied force. <b>Conclusions:</b> The TATT in the tibial fixation condition produced more significant axial movement of the talus (mm) relative to the tibia than the non-tibial fixation condition did. The detection of the magnitudes of movement showed good reliability (ICC: 0.75 to 0.92). The technique was well tolerated at all force magnitudes, with the tibial fixation condition being the most tolerable.

Authors

Institutions

Publication Details

Journal
Journal of Functional Morphology and Kinesiology
Published
2024-09-15
DOI
https://doi.org/10.3390/jfmk9030163
Primary Topic
Foot and Ankle Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Relevance of Tibial Fixation during Tibiotarsal Joint Traction: Descriptive Cross-Sectional Study

Vanessa González-Rueda, Sergi Gassó-Villarejo, Carlos López-de–Celis, Elena Estébanez-de-Miguel et al.
Journal of Functional Morphology and Kinesiology
Foot and Ankle Surgery
article

Relevance of Tibial Fixation during Tibiotarsal Joint Traction: Descriptive Cross-Sectional Study

Vanessa González-Rueda, Sergi Gassó-Villarejo, Carlos López-de–Celis, Elena Estébanez-de-Miguel, Jacobo Rodríguez‐Sanz, Erik García-Ribell, Elena Bueno-Gracía
article en

Abstract

<b>Background:</b> The effect of tibial fixation on the movement of the talus during the tibiotarsal axial traction technique (TATT) is unknown. The aim was to evaluate the effect on the tibiotarsus when applying three different intensities of TATT force with or without tibial fixation in healthy subjects, and to assess the reliability of detecting the different forces applied. Also, the discomfort generated during the technique would be analysed. <b>Methods:</b> A cross-sectional study was conducted in thirty lower limbs. Three magnitudes of TATT force in an open-packed position were applied in tibial fixation and non-fixation conditions. The axial traction movement was measured by ultrasound, and the magnitudes of the force applied during low-medium and high TATT force were recorded in both conditions. Patients were asked about the level of discomfort perceived during the technique. <b>Results:</b> The most significant distance increase (mm) was observed in the tibial fixation condition at all magnitudes of the TATT (F = 102.693, <i>p</i> < 0.001). The discomfort sensation (numeric rating scale, "NRS") was higher in the non-fixation condition (<i>p</i> > 0.05). The application of the technique showed good reliability (>0.75 ICC) for the detection of the applied force. <b>Conclusions:</b> The TATT in the tibial fixation condition produced more significant axial movement of the talus (mm) relative to the tibia than the non-tibial fixation condition did. The detection of the magnitudes of movement showed good reliability (ICC: 0.75 to 0.92). The technique was well tolerated at all force magnitudes, with the tibial fixation condition being the most tolerable.

Journal of Functional Morphology and KinesiologyVol. 9(3)
Universidad de Zaragoza (ES), Universitat Internacional de Catalunya (ES), Institut Universitari d'Investigació en Atenció Primària Jordi Gol (ES)
Openalex Percentile: Top 78%
Foot and Ankle Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.