Use of Phase Discontinuity Features in Pocket-Worn Accelerometer to detect Coughs

Cough is considered to be the major symptom of most respiratory problems and due to the recent COVID-19 pandemic cough detection has become a major area of interest. This paper addresses the issue of cough detection using a simple detection methodology using Fast Fourier Transform (FFT) analysis peak detection technique on accelerometer data worn in shirt pocket where smart phones are commonly carried. This methodology measures the peaks on the negative side of the FFT plots indicating phase discontinuity due to coughs or lack of best results are seen on accelerometer signals along directions perpendicular to the chest surface (Z axis) and the vertical height (Y axis) of the test subjects in the different frequency bands 1,2,3 (1-2Hz, 2-4Hz and 4-6Hz). The results indicate that the number peaks in bands 2 and 3 (2-4Hz and 4-6Hz) are significantly higher for detecting cough patterns quite consistently in 2 test subjects of height and weight 1-1.8 meters and 16–64 kilograms.

Authors

Institutions

Publication Details

Published
2024-08-11
DOI
https://doi.org/10.1109/mwscas60917.2024.10658769
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Use of Phase Discontinuity Features in Pocket-Worn Accelerometer to detect Coughs

Sudarsini Tekkam Gnanasekar, Kruthi Doddabasappla, Rushi Vyas
Advanced Chemical Sensor Technologies
article

Use of Phase Discontinuity Features in Pocket-Worn Accelerometer to detect Coughs

Sudarsini Tekkam Gnanasekar, Kruthi Doddabasappla, Rushi Vyas
article en

Abstract

Cough is considered to be the major symptom of most respiratory problems and due to the recent COVID-19 pandemic cough detection has become a major area of interest. This paper addresses the issue of cough detection using a simple detection methodology using Fast Fourier Transform (FFT) analysis peak detection technique on accelerometer data worn in shirt pocket where smart phones are commonly carried. This methodology measures the peaks on the negative side of the FFT plots indicating phase discontinuity due to coughs or lack of best results are seen on accelerometer signals along directions perpendicular to the chest surface (Z axis) and the vertical height (Y axis) of the test subjects in the different frequency bands 1,2,3 (1-2Hz, 2-4Hz and 4-6Hz). The results indicate that the number peaks in bands 2 and 3 (2-4Hz and 4-6Hz) are significantly higher for detecting cough patterns quite consistently in 2 test subjects of height and weight 1-1.8 meters and 16–64 kilograms.

University of Calgary (CA)
Natural Sciences and Engineering Research Council of Canada
Openalex Percentile: Top 86%
Advanced Chemical Sensor Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.