Comparative evaluation of blood contamination on the push-out bond strength of mineral trioxide aggregate, Biodentine, and bone cement in furcation perforation repair: An in vitro study

ABSTRACT Aim: This in vitro study was designed to compare the effect of blood contamination on the push-out bond strength of mineral trioxide aggregate (MTA), Biodentine, and bone cement. Methods: Seventy-eight human mandibular molars with furcation were selected and decoronated at the cementoenamel junction. The samples were mounted 3 mm below the furcation area into the acrylic resin. A perforation in the center of the furcation was made using a round carbide bur size 3 with a diameter of 1.2 mm. Then, the perforation was enlarged up to a standardized diameter of 1.3 mm using a size 5 Gates-Glidden drill. The samples were randomly divided into three groups. Based on blood contamination status, each group ( n = 26) was further subdivided into two subgroups ( n = 13). Whole fresh human blood was obtained from the principal investigator of the research group. A 27-gauge syringe was used to inject blood into the perforated furcal area. A piece of gelatin was packed under the furcal area using a condenser. MTA, Biodentine, and bone cement were mixed according to the manufacturer’s recommendations and compacted into the perforation. A universal testing machine was used to evaluate the push-out bond strength. The results were analyzed using one-way analysis of variance followed by Tukey’s post hoc test ( P < 0.05). Results: In the experimental groups with blood contamination, Group 2A exhibited statistically significant push-out bond strength values compared with Group 1A and Group 3A. In the groups without blood contamination, Group 2B showed statistically significant push-out bond strength values compared with Group 1B and Group 3B. Irrespective of the blood contamination status, Group 3 exhibited higher push-out bond strength values than Group 1, with no statistically significant difference between the groups. No significant difference was observed within the groups. Conclusion: Biodentine showed promising results as a better perforation repair material irrespective of the status of blood contamination. Bone cement can be a viable alternative material for furcation perforation repair compared with MTA.

Authors

Institutions

Publication Details

Journal
Endodontology
Published
2024-09-21
DOI
https://doi.org/10.4103/endo.endo_52_24
Citations
2
Primary Topic
Endodontics and Root Canal Treatments
Type
article
Field-Weighted Citation Impact
0.99
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative evaluation of blood contamination on the push-out bond strength of mineral trioxide aggregate, Biodentine, and bone cement in furcation perforation repair: An in vitro study

Girija S Sajjan, Swapnika Gudapati, V. Santosh Kumar, R. Kalyan Satish et al.
2 citations
Endodontology
Endodontics and Root Canal Treatments
0.99
article

Comparative evaluation of blood contamination on the push-out bond strength of mineral trioxide aggregate, Biodentine, and bone cement in furcation perforation repair: An in vitro study

Girija S Sajjan, Swapnika Gudapati, V. Santosh Kumar, R. Kalyan Satish, Madhu Varma K
article en
2 citations

Abstract

ABSTRACT Aim: This in vitro study was designed to compare the effect of blood contamination on the push-out bond strength of mineral trioxide aggregate (MTA), Biodentine, and bone cement. Methods: Seventy-eight human mandibular molars with furcation were selected and decoronated at the cementoenamel junction. The samples were mounted 3 mm below the furcation area into the acrylic resin. A perforation in the center of the furcation was made using a round carbide bur size 3 with a diameter of 1.2 mm. Then, the perforation was enlarged up to a standardized diameter of 1.3 mm using a size 5 Gates-Glidden drill. The samples were randomly divided into three groups. Based on blood contamination status, each group ( n = 26) was further subdivided into two subgroups ( n = 13). Whole fresh human blood was obtained from the principal investigator of the research group. A 27-gauge syringe was used to inject blood into the perforated furcal area. A piece of gelatin was packed under the furcal area using a condenser. MTA, Biodentine, and bone cement were mixed according to the manufacturer’s recommendations and compacted into the perforation. A universal testing machine was used to evaluate the push-out bond strength. The results were analyzed using one-way analysis of variance followed by Tukey’s post hoc test ( P < 0.05). Results: In the experimental groups with blood contamination, Group 2A exhibited statistically significant push-out bond strength values compared with Group 1A and Group 3A. In the groups without blood contamination, Group 2B showed statistically significant push-out bond strength values compared with Group 1B and Group 3B. Irrespective of the blood contamination status, Group 3 exhibited higher push-out bond strength values than Group 1, with no statistically significant difference between the groups. No significant difference was observed within the groups. Conclusion: Biodentine showed promising results as a better perforation repair material irrespective of the status of blood contamination. Bone cement can be a viable alternative material for furcation perforation repair compared with MTA.

EndodontologyVol. 36(4)
MNR Dental College and Hospital (IN), Vishnu Dental College
Openalex Percentile: Top 24%
Endodontics and Root Canal Treatments
0.99
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.