Comparing Implant Macrodesigns and Their Impact on Stability: A Year-Long Clinical Study

<i>Background and Objectives</i>: The aim of this study was to clinically evaluate the primary and secondary stability of dental implants with different macrodesigns using resonance frequency analysis and to determine whether implant design and length influence implant stability. <i>Materials and methods</i>: This study included 48 healthy patients receiving dental implants, and a pre-implant planning protocol was used, which involved detailed bone analysis, clinical examinations, and Cone beam computed tomography (CBCT) analysis. The implants were of various types and dimensions (Alpha-Bio Tec (Israel), DFI, SPI, and NEO), and the surgical procedures were performed using standard methods. Implant stability was measured using resonance frequency analysis (RFA) immediately after placement and after 3, 6, and 12 months. The total number of implants placed in all patients was 96. <i>Results</i>: The average primary stability value for 10 mm SPI implants placed in the maxilla was 68.2 ± 1.7 Implant Stability Quotient (ISQ) units, while for 10 mm NEO implants, it was 74.0 ± 0.9. The average primary stability value for a 10 mm DFI implant placed in the mandible was 72.8 ± 1.2 ISQ, while for a 10 mm NEO implant placed in the mandible, it was 76.3 ± 0.8 ISQ. Based on the Friedman ANOVA test, the differences in the stability measurements for the 10 mm and 11.5 mm SPI implants and for the 10 mm and 11.5 mm NEO implants in the maxilla on day 0 and after 3, 6, and 12 months were significant at <i>p</i> < 0.05. Similarly, based on the Friedman ANOVA test, the differences in the stability measurements for the 10 mm and 11.5 mm DFI implants and for the 10 mm and 11.5 mm NEO implants in the mandible on day 0 and after 3, 6, and 12 months were significant at <i>p</i> < 0.05 (<i>p</i> = 0.00000). <i>Conclusions</i>: Universal tapered implants of the NEO type stood out as the optimal choice, as they provided statistically significantly higher primary stability in both soft and hard bone types compared to other implants. The implant length did not significantly affect this stability.

Authors

Institutions

Publication Details

Journal
Medicina
Published
2024-09-21
DOI
https://doi.org/10.3390/medicina60091546
Citations
2
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.99
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparing Implant Macrodesigns and Their Impact on Stability: A Year-Long Clinical Study

Raša Mladenović, Mirko Mikić, Dimitar Tasevski, Sasa Dabic et al.
2 citations
Medicina
Dental Implant Techniques and Outcomes
0.99
article

Comparing Implant Macrodesigns and Their Impact on Stability: A Year-Long Clinical Study

Raša Mladenović, Mirko Mikić, Dimitar Tasevski, Sasa Dabic, Julie Popovski
article en
2 citations

Abstract

<i>Background and Objectives</i>: The aim of this study was to clinically evaluate the primary and secondary stability of dental implants with different macrodesigns using resonance frequency analysis and to determine whether implant design and length influence implant stability. <i>Materials and methods</i>: This study included 48 healthy patients receiving dental implants, and a pre-implant planning protocol was used, which involved detailed bone analysis, clinical examinations, and Cone beam computed tomography (CBCT) analysis. The implants were of various types and dimensions (Alpha-Bio Tec (Israel), DFI, SPI, and NEO), and the surgical procedures were performed using standard methods. Implant stability was measured using resonance frequency analysis (RFA) immediately after placement and after 3, 6, and 12 months. The total number of implants placed in all patients was 96. <i>Results</i>: The average primary stability value for 10 mm SPI implants placed in the maxilla was 68.2 ± 1.7 Implant Stability Quotient (ISQ) units, while for 10 mm NEO implants, it was 74.0 ± 0.9. The average primary stability value for a 10 mm DFI implant placed in the mandible was 72.8 ± 1.2 ISQ, while for a 10 mm NEO implant placed in the mandible, it was 76.3 ± 0.8 ISQ. Based on the Friedman ANOVA test, the differences in the stability measurements for the 10 mm and 11.5 mm SPI implants and for the 10 mm and 11.5 mm NEO implants in the maxilla on day 0 and after 3, 6, and 12 months were significant at <i>p</i> < 0.05. Similarly, based on the Friedman ANOVA test, the differences in the stability measurements for the 10 mm and 11.5 mm DFI implants and for the 10 mm and 11.5 mm NEO implants in the mandible on day 0 and after 3, 6, and 12 months were significant at <i>p</i> < 0.05 (<i>p</i> = 0.00000). <i>Conclusions</i>: Universal tapered implants of the NEO type stood out as the optimal choice, as they provided statistically significantly higher primary stability in both soft and hard bone types compared to other implants. The implant length did not significantly affect this stability.

MedicinaVol. 60(9)
University of Kragujevac (RS), University of Montenegro (ME)
Openalex Percentile: Top 24%
Dental Implant Techniques and Outcomes
0.99
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.