Development of novel ionization chambers for reference dosimetry in electron flash radiotherapy

This study confirmed that the CCE of ion chambers depends strongly on the electrode spacing and the electric field strength, and also on the DPP and the PW of the UHDR beam. A significant finding of this study is that although chamber performance does depend on PW, the effect on the CCE becomes negligible with reduced electrode spacing and increased electric field. A CCE of ≥95% was achieved for DPPs of up to 5 Gy with no observable dependence on PW using the A30 chamber, while still achieving an acceptable performance in conventional dose rate beams, opening up the possibility for this type of chamber to be used as a reference class chamber for calibration purposes of electron FLASH beamlines.

Authors

Institutions

Publication Details

Journal
Medical Physics
Published
2024-09-23
DOI
https://doi.org/10.1002/mp.17425
Citations
15
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
6.28

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of novel ionization chambers for reference dosimetry in electron flash radiotherapy

Ahtesham Ullah Khan, Sam Beddar, Shannon Holmes, Larry A. DeWerd et al.
15 citations
Medical Physics
Radiation Therapy and Dosimetry
6.28
article

Development of novel ionization chambers for reference dosimetry in electron flash radiotherapy

Ahtesham Ullah Khan, Sam Beddar, Shannon Holmes, Larry A. DeWerd, Brian D. Hooten, Kevin Liu, Emil Schüler
article en
15 citations

Abstract

This study confirmed that the CCE of ion chambers depends strongly on the electrode spacing and the electric field strength, and also on the DPP and the PW of the UHDR beam. A significant finding of this study is that although chamber performance does depend on PW, the effect on the CCE becomes negligible with reduced electrode spacing and increased electric field. A CCE of ≥95% was achieved for DPPs of up to 5 Gy with no observable dependence on PW using the A30 chamber, while still achieving an acceptable performance in conventional dose rate beams, opening up the possibility for this type of chamber to be used as a reference class chamber for calibration purposes of electron FLASH beamlines.

Medical PhysicsVol. 51(12)
Northwestern University (US), The University of Texas MD Anderson Cancer Center (US), University of Wisconsin–Madison (US), Northwestern Memorial Hospital (US), Standard Imaging (United States) (US), The University of Texas Health Science Center at Houston (US)
Cancer Prevention and Research Institute of Texas, University of Texas Health Science Center at Houston, National Institutes of Health, University of Texas MD Anderson Cancer Center, National Cancer Institute
Affordable and clean energy
Openalex Percentile: Top 3%
Radiation Therapy and Dosimetry
6.28
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.