Ceramic Nanotubes—Conducting Polymer Assemblies with Potential Application as Chemosensors for Breath Ammonia Detection in Chronic Kidney Disease

This paper describes the process of producing chemosensors based on hybrid nanostructures obtained from Al2O3, as well as ZnO ceramic nanotubes and the following conducting polymers: poly(3-hexylthiophene), polyaniline emeraldine-base (PANI-EB), and poly(3, 4-ethylenedioxythiophene)-polystyrene sulfonate. The process for creating ceramic nanotubes involves three steps: creating polymer fiber nets using poly(methyl methacrylate), depositing ceramic films onto the nanofiber nets using magnetron deposition, and heating the nanotubes to 600 °C to burn off the polymer support completely. The technology for obtaining hybrid nanostructures from ceramic nanotubes and conducting polymers is drop-casting. AFM analysis emphasized a higher roughness, mainly in the case of PANI-EB, for both nanotube types, with a much larger grain size dimension of over 5 μm. The values of the parameter Rku were close or slightly above 3, indicating, in all cases, the formation of layers predominantly characterized by peaks and not by depressions, with a Gaussian distribution. An ink-jet printer was used to generate chemiresistors from ceramic nanotubes and PANI-EB structures, and the metallization was made with commercial copper ink for printed electronics. Calibration curves were experimentally generated for both sensing structures across a wider range of NH3 concentrations in air, reaching up to 5 ppm. A 0.5 ppm detection limit was established. The curve for the ZnO:PANI-EB structure presented high linearity and lower resistance values. The sensor could be used in medical diagnosis for the analysis of breath ammonia and biomarkers for predicting CKD in stages higher than 1. The threshold value of 1 ppm represents a feasible value for the presented sensor, which can be defined as a simple, low-value and robust device for individual use, beneficial at the patient level.

Authors

Institutions

Publication Details

Journal
Chemosensors
Published
2024-09-23
DOI
https://doi.org/10.3390/chemosensors12090198
Citations
2
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.37
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ceramic Nanotubes—Conducting Polymer Assemblies with Potential Application as Chemosensors for Breath Ammonia Detection in Chronic Kidney Disease

Oliver Daniel Schreiner, Alexandru Trandabăţ, Thomas Gabriel Schreiner, Sebastian Aradoaei et al.
2 citations
Chemosensors
Advanced Chemical Sensor Technologies
0.37
article

Ceramic Nanotubes—Conducting Polymer Assemblies with Potential Application as Chemosensors for Breath Ammonia Detection in Chronic Kidney Disease

Oliver Daniel Schreiner, Alexandru Trandabăţ, Thomas Gabriel Schreiner, Sebastian Aradoaei, Romeo Cristian Ciobanu
article en
2 citations

Abstract

This paper describes the process of producing chemosensors based on hybrid nanostructures obtained from Al2O3, as well as ZnO ceramic nanotubes and the following conducting polymers: poly(3-hexylthiophene), polyaniline emeraldine-base (PANI-EB), and poly(3, 4-ethylenedioxythiophene)-polystyrene sulfonate. The process for creating ceramic nanotubes involves three steps: creating polymer fiber nets using poly(methyl methacrylate), depositing ceramic films onto the nanofiber nets using magnetron deposition, and heating the nanotubes to 600 °C to burn off the polymer support completely. The technology for obtaining hybrid nanostructures from ceramic nanotubes and conducting polymers is drop-casting. AFM analysis emphasized a higher roughness, mainly in the case of PANI-EB, for both nanotube types, with a much larger grain size dimension of over 5 μm. The values of the parameter Rku were close or slightly above 3, indicating, in all cases, the formation of layers predominantly characterized by peaks and not by depressions, with a Gaussian distribution. An ink-jet printer was used to generate chemiresistors from ceramic nanotubes and PANI-EB structures, and the metallization was made with commercial copper ink for printed electronics. Calibration curves were experimentally generated for both sensing structures across a wider range of NH3 concentrations in air, reaching up to 5 ppm. A 0.5 ppm detection limit was established. The curve for the ZnO:PANI-EB structure presented high linearity and lower resistance values. The sensor could be used in medical diagnosis for the analysis of breath ammonia and biomarkers for predicting CKD in stages higher than 1. The threshold value of 1 ppm represents a feasible value for the presented sensor, which can be defined as a simple, low-value and robust device for individual use, beneficial at the patient level.

ChemosensorsVol. 12(9)
Grigore T. Popa University of Medicine and Pharmacy (RO), Gheorghe Asachi Technical University of Iași (RO)
Openalex Percentile: Top 43%
Advanced Chemical Sensor Technologies
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines