The effect of percutaneous and transcutaneous BAHA on hearing and subjective auditory abilities: A comparative study

Hearing loss significantly affects communication, social interactions, and the overall quality of life. The bone-anchored hearing aid (BAHA) is an implantable system that bypasses the outer and middle ear to directly stimulate the cochlea through bone conduction. This study aimed to compare hearing performance and subjective auditory ability improvements between transcutaneous and percutaneous BAHA devices using audiological assessments and Speech, Spatial and Qualities of Hearing Scale. This cross-sectional prospective study included 29 participants aged 14 to 69 years who had used BAHA for at least 6 months. Both Cochlear Baha System's percutaneous (connect) and transcutaneous (attract) implants were evaluated. Audiological assessments involved pure-tone audiometry, speech recognition threshold, and free-field (FF) audiometry, while subjective auditory ability was measured using the Turkish Speech, Spatial and Qualities of Hearing scale (Tr-SSQ). Significant improvements in FF audiometry averages and speech recognition thresholds were observed with BAHA compared to without BAHA (P < .001). Both implant types provided similar FF averages, speech audiometry results, and Tr-SSQ outcomes, with no significant differences between them. Tr-SSQ scores showed substantial satisfaction, indicating significant improvements in speech perception, spatial perception, and hearing quality with BAHA (P < .001). The findings align with previous research, demonstrating that BAHA is a reliable and effective solution for hearing rehabilitation. The study also emphasized the importance of using both audiological test results and daily hearing function scales to comprehensively evaluate the benefits of hearing rehabilitation in real-world environments. In conclusion, BAHA, regardless of the implant type, can provide predictable and lasting improvements in hearing thresholds and daily hearing abilities, making it a valuable option for patients with conductive hearing loss.

Authors

Institutions

Publication Details

Journal
Medicine
Published
2024-09-20
DOI
https://doi.org/10.1097/md.0000000000039697
Citations
4
Primary Topic
Hearing Loss and Rehabilitation
Type
article
Field-Weighted Citation Impact
1.37

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The effect of percutaneous and transcutaneous BAHA on hearing and subjective auditory abilities: A comparative study

Gülce Kirazlı, Enis Alpin Güneri̇, Yüksel Olgun, Hande Evin Eskicioğlu et al.
4 citations
Medicine
Hearing Loss and Rehabilitation
1.37
article

The effect of percutaneous and transcutaneous BAHA on hearing and subjective auditory abilities: A comparative study

Gülce Kirazlı, Enis Alpin Güneri̇, Yüksel Olgun, Hande Evin Eskicioğlu, Selhan Gürkan, Günay Kırkım, Taner Kemal Erdağ, Serpil Mungan Durankaya, Ilayda Kiremitçi
article en
4 citations

Abstract

Hearing loss significantly affects communication, social interactions, and the overall quality of life. The bone-anchored hearing aid (BAHA) is an implantable system that bypasses the outer and middle ear to directly stimulate the cochlea through bone conduction. This study aimed to compare hearing performance and subjective auditory ability improvements between transcutaneous and percutaneous BAHA devices using audiological assessments and Speech, Spatial and Qualities of Hearing Scale. This cross-sectional prospective study included 29 participants aged 14 to 69 years who had used BAHA for at least 6 months. Both Cochlear Baha System's percutaneous (connect) and transcutaneous (attract) implants were evaluated. Audiological assessments involved pure-tone audiometry, speech recognition threshold, and free-field (FF) audiometry, while subjective auditory ability was measured using the Turkish Speech, Spatial and Qualities of Hearing scale (Tr-SSQ). Significant improvements in FF audiometry averages and speech recognition thresholds were observed with BAHA compared to without BAHA (P < .001). Both implant types provided similar FF averages, speech audiometry results, and Tr-SSQ outcomes, with no significant differences between them. Tr-SSQ scores showed substantial satisfaction, indicating significant improvements in speech perception, spatial perception, and hearing quality with BAHA (P < .001). The findings align with previous research, demonstrating that BAHA is a reliable and effective solution for hearing rehabilitation. The study also emphasized the importance of using both audiological test results and daily hearing function scales to comprehensively evaluate the benefits of hearing rehabilitation in real-world environments. In conclusion, BAHA, regardless of the implant type, can provide predictable and lasting improvements in hearing thresholds and daily hearing abilities, making it a valuable option for patients with conductive hearing loss.

MedicineVol. 103(38)
Dokuz Eylül University (TR), Ege University (TR)
Dokuz Eylül Üniversitesi
Openalex Percentile: Top 20%
Hearing Loss and Rehabilitation
1.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.