Super-Resolution Ultrasound Imaging for Analysis of Microbubbles Cluster by Acoustic Vortex Tweezers

Using acoustic vortex tweezers (AVTs) to spatially accumulate microbubbles (MBs) shows promise for enhancing drug delivery efficiency and reducing off-target effects. The strong echogenicity of accumulated MBs also improves diagnostics via conventional ultrasound (US) B-mode imaging. However, the annular high-pressure distribution of AVT inhibits MBs inflow at the inlet, reducing MBs collection. The spatial resolution of US B-mode imaging further limits theranostic applications of AVT-mediated MBs accumulation. To address these challenges, we integrated an AVT waveform with volumetric super-resolution imaging (VSRI) to monitor the dynamic growth of MBs cluster during accumulation. We used a 5-MHz 2-D array transducer for VSRI, employing plane wave pulses interleaved with accumulating pulses to retain MBs at a flow rate of 0.023-0.047 mL/s in a 3-mm vessel phantom. An asymmetrical AVT waveform (AVT ) was produced by modulating the pressure at the MBs inlet compared to the outlet. The effectiveness was validated in rat cerebral vessels for real-time volumetric tracking of MBs clusters. Microscopy observations showed that AVT could quickly gather flowing MBs into cluster without repelling them at a flow rate of 0.023 mL/s. Statistical results indicated that microscopic data correlated better with VSRI than with B-mode images, suggesting VSRI suffices to detect the dynamics of AVT -actuated MBs accumulation in real-time. Additionally, VSRI detected a significant increase in MBs cluster size over time during AVT in the superior sagittal sinus (SSS) of the rat brain. These findings demonstrate that the proposed strategy can accumulate the flowing MBs at a desired location and simultaneously observe this phenomenon.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
Published
2024-09-23
DOI
https://doi.org/10.1109/tuffc.2024.3466119
Citations
4
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
0.74

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Super-Resolution Ultrasound Imaging for Analysis of Microbubbles Cluster by Acoustic Vortex Tweezers

Chih‐Kuang Yeh, Ching‐Hsiang Fan, Thi-Nhan Phan, Wei-Chen Lo et al.
4 citations
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
Ultrasound and Hyperthermia Applications
0.74
article

Super-Resolution Ultrasound Imaging for Analysis of Microbubbles Cluster by Acoustic Vortex Tweezers

Chih‐Kuang Yeh, Ching‐Hsiang Fan, Thi-Nhan Phan, Wei-Chen Lo, Chung-Han Huang
article en
4 citations

Abstract

Using acoustic vortex tweezers (AVTs) to spatially accumulate microbubbles (MBs) shows promise for enhancing drug delivery efficiency and reducing off-target effects. The strong echogenicity of accumulated MBs also improves diagnostics via conventional ultrasound (US) B-mode imaging. However, the annular high-pressure distribution of AVT inhibits MBs inflow at the inlet, reducing MBs collection. The spatial resolution of US B-mode imaging further limits theranostic applications of AVT-mediated MBs accumulation. To address these challenges, we integrated an AVT waveform with volumetric super-resolution imaging (VSRI) to monitor the dynamic growth of MBs cluster during accumulation. We used a 5-MHz 2-D array transducer for VSRI, employing plane wave pulses interleaved with accumulating pulses to retain MBs at a flow rate of 0.023-0.047 mL/s in a 3-mm vessel phantom. An asymmetrical AVT waveform (AVT ) was produced by modulating the pressure at the MBs inlet compared to the outlet. The effectiveness was validated in rat cerebral vessels for real-time volumetric tracking of MBs clusters. Microscopy observations showed that AVT could quickly gather flowing MBs into cluster without repelling them at a flow rate of 0.023 mL/s. Statistical results indicated that microscopic data correlated better with VSRI than with B-mode images, suggesting VSRI suffices to detect the dynamics of AVT -actuated MBs accumulation in real-time. Additionally, VSRI detected a significant increase in MBs cluster size over time during AVT in the superior sagittal sinus (SSS) of the rat brain. These findings demonstrate that the proposed strategy can accumulate the flowing MBs at a desired location and simultaneously observe this phenomenon.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency ControlVol. 71(12: Breaking the Resolution)
National Tsing Hua University (TW), National Cheng Kung University (TW)
Ministry of Science and Technology, Taiwan
Affordable and clean energy
Openalex Percentile: Top 32%
Ultrasound and Hyperthermia Applications
0.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.