Research of MEMS Pressure Sensor Stability With PDA-NFL Circuit

The stability of pressure sensor chip output characteristics using the piezoresistive method in the form of microelectromechanical system (MEMS) is one of the most important features for sensors. The research analyzes the changes in the useful signal, as well as errors of highly sensitive pressure sensor chips. The main feature of this development is the application of a new electrical circuit in the form of piezoresistive differential amplifier with negative feedback loop (PDA-NFL) utilizing bipolar junction transistors (BJTs), which allows to achieve a balance between high sensitivity, small chip area, and low errors. This research considers the variations of two batch with pressure sensor chip PDA-NFL samples (area <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$4.00\times 4.00$ </tex-math></inline-formula> mm2) for the range of 1 kPa after 4.5 years [eight samples, sensitivity <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${S}_{\text {1 after}} =$ </tex-math></inline-formula> (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$40.6~\pm ~6.4$ </tex-math></inline-formula>) mV/V/kPa, nonlinearity <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$2K_{\text {NL 1 after}} =$ </tex-math></inline-formula> (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$0.81~\pm ~0.15$ </tex-math></inline-formula>)%/FS] and range of 5 kPa after 3.0 years [14 samples, sensitivity <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${S}_{\text {5 after}} =$ </tex-math></inline-formula> (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$11.2~\pm ~1.8$ </tex-math></inline-formula>) mV/V/kPa, nonlinearity <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$2K_{\text {NL 5 after}} =$ </tex-math></inline-formula> (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$0.10~\pm ~0.06$ </tex-math></inline-formula>)%/FS]. The study demonstrates the unidirectional influence of residual mechanical stresses (RMS) from the pressure sensor assembly design on sensitivity and nonlinearity when pressure is applied from different sides of chip and temperature hysteresis errors.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2024-09-23
DOI
https://doi.org/10.1109/jsen.2024.3454952
Citations
23
Primary Topic
Advanced Sensor and Control Systems
Type
article
Field-Weighted Citation Impact
7.55
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research of MEMS Pressure Sensor Stability With PDA-NFL Circuit

Mikhail Basov
23 citations
IEEE Sensors Journal
Advanced Sensor and Control Systems
7.55
article

Research of MEMS Pressure Sensor Stability With PDA-NFL Circuit

Mikhail Basov
article en
23 citations

Abstract

The stability of pressure sensor chip output characteristics using the piezoresistive method in the form of microelectromechanical system (MEMS) is one of the most important features for sensors. The research analyzes the changes in the useful signal, as well as errors of highly sensitive pressure sensor chips. The main feature of this development is the application of a new electrical circuit in the form of piezoresistive differential amplifier with negative feedback loop (PDA-NFL) utilizing bipolar junction transistors (BJTs), which allows to achieve a balance between high sensitivity, small chip area, and low errors. This research considers the variations of two batch with pressure sensor chip PDA-NFL samples (area <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$4.00\times 4.00$ </tex-math></inline-formula> mm2) for the range of 1 kPa after 4.5 years [eight samples, sensitivity <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${S}_{\text {1 after}} =$ </tex-math></inline-formula> (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$40.6~\pm ~6.4$ </tex-math></inline-formula>) mV/V/kPa, nonlinearity <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$2K_{\text {NL 1 after}} =$ </tex-math></inline-formula> (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$0.81~\pm ~0.15$ </tex-math></inline-formula>)%/FS] and range of 5 kPa after 3.0 years [14 samples, sensitivity <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${S}_{\text {5 after}} =$ </tex-math></inline-formula> (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$11.2~\pm ~1.8$ </tex-math></inline-formula>) mV/V/kPa, nonlinearity <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$2K_{\text {NL 5 after}} =$ </tex-math></inline-formula> (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$0.10~\pm ~0.06$ </tex-math></inline-formula>)%/FS]. The study demonstrates the unidirectional influence of residual mechanical stresses (RMS) from the pressure sensor assembly design on sensitivity and nonlinearity when pressure is applied from different sides of chip and temperature hysteresis errors.

IEEE Sensors JournalVol. 24(21)
All Russia Research Institute of Automatics (RU), All-Russian Research and Design Institute of Nuclear and Power Engineering (RU), All-Russian Scientific Research Institute for Operation of Nuclear Power Plants (RU)
Affordable and clean energy
Openalex Percentile: Top 2%
Advanced Sensor and Control Systems
7.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.