Coupled Discrete Phase and Eulerian Wall Film Models for Drug Deposition Efficacy Analysis in Human Respiratory Airways

The current study explores the effectiveness of drug particle deposition into human respiratory airways to cure various pulmonary-bound ailments. It has been assumed that drug solutions are inhaled in the form of tiny droplets or mist, which after striking create a thin layer along the inner surface of airways where the virus initially resides to infect the human body. A coupled Eulerian wall film (EWF) and discrete phase model (DPM) based simulation approach is used to capture these dynamics. Here, the Lagrangian DPM technique tracks the dynamics of tiny droplets, while the liquid layer formation after striking is captured using the Eulerian thin film approximations or the EWF model. Previous studies in this field primarily employed only the DPM method, which is inadequate to predict the poststriking dynamics of drug layer deposition and their spread to neutralize the respiratory virus. The drug delivery effectiveness is characterized by three different particle sizes, 1, 5, and 10 μm at the inhalation rates of 15, 30, and 60 L per minute (LPM). It has been found that the size of the drug particles significantly influences drug delivery effectiveness. The film thickness increases monotonically with particle sizes and inhalation rates. However, this increase in averaged film thickness is prominent in the range 5 to 10 μm (≈60%) compared to 1 to 5 μm (≈10%) droplet sizes at generation level 4 (G4). The other deposition parameters, e.g., deposition fraction, deposition density, and area coverage) roughly show similar behavior with the increase in droplet sizes. Therefore, it is recommended to vary the droplet sizes between 5 and 10 μm for better deposition effectiveness. The sizes of more than 10 μm mostly stuck into the oral cavity and cannot reach the targeted generations. In contrast, less than 5 μm may reach much deeper generations than the targeted one.

Authors

Institutions

Publication Details

Journal
Molecular Pharmaceutics
Published
2024-09-23
DOI
https://doi.org/10.1021/acs.molpharmaceut.4c00482
Citations
4
Primary Topic
Inhalation and Respiratory Drug Delivery
Type
article
Field-Weighted Citation Impact
1.68

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Coupled Discrete Phase and Eulerian Wall Film Models for Drug Deposition Efficacy Analysis in Human Respiratory Airways

B. Kiran Naik, Kishore Singh Patel, Sameer Kumar Verma
4 citations
Molecular Pharmaceutics
Inhalation and Respiratory Drug Delivery
1.68
article

Coupled Discrete Phase and Eulerian Wall Film Models for Drug Deposition Efficacy Analysis in Human Respiratory Airways

B. Kiran Naik, Kishore Singh Patel, Sameer Kumar Verma
article en
4 citations

Abstract

The current study explores the effectiveness of drug particle deposition into human respiratory airways to cure various pulmonary-bound ailments. It has been assumed that drug solutions are inhaled in the form of tiny droplets or mist, which after striking create a thin layer along the inner surface of airways where the virus initially resides to infect the human body. A coupled Eulerian wall film (EWF) and discrete phase model (DPM) based simulation approach is used to capture these dynamics. Here, the Lagrangian DPM technique tracks the dynamics of tiny droplets, while the liquid layer formation after striking is captured using the Eulerian thin film approximations or the EWF model. Previous studies in this field primarily employed only the DPM method, which is inadequate to predict the poststriking dynamics of drug layer deposition and their spread to neutralize the respiratory virus. The drug delivery effectiveness is characterized by three different particle sizes, 1, 5, and 10 μm at the inhalation rates of 15, 30, and 60 L per minute (LPM). It has been found that the size of the drug particles significantly influences drug delivery effectiveness. The film thickness increases monotonically with particle sizes and inhalation rates. However, this increase in averaged film thickness is prominent in the range 5 to 10 μm (≈60%) compared to 1 to 5 μm (≈10%) droplet sizes at generation level 4 (G4). The other deposition parameters, e.g., deposition fraction, deposition density, and area coverage) roughly show similar behavior with the increase in droplet sizes. Therefore, it is recommended to vary the droplet sizes between 5 and 10 μm for better deposition effectiveness. The sizes of more than 10 μm mostly stuck into the oral cavity and cannot reach the targeted generations. In contrast, less than 5 μm may reach much deeper generations than the targeted one.

Molecular PharmaceuticsVol. 21(10)
National Institute of Technology Rourkela (IN)
Indian Council of Medical Research, National Institute of Technology Rourkela
Zero hunger
Openalex Percentile: Top 15%
Inhalation and Respiratory Drug Delivery
1.68
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.