Development of a Polymer Ultrasound Contrast Agent Incorporating Nested Carbon Nanodots

Polymer microbubbles have garnered broad interest as potential theranostic agents. However, the capabilities of polymer MBs can be greatly enhanced, particularly regarding the imaging performance and functional versatility of the platform. This study investigates integrating fluorescent carbon nanodots within polylactic acid (PLA) microbubbles. First, the formulations are characterized by their size, microbubble counts, zeta potential, and resonance frequency. Then, the fluorescence capabilities, nanoparticle loading, and acoustic capabilities are examined. Unmodified (U-), carboxylated (C-), and aminated graphene quantum dots (A-GQDs) were separately suspended and synthesized at a 2% w/w ratio with PLA in the organic phase of the water/oil/water double emulsion process. The new microbubbles were characterized using an AccuSizer, Zetasizer, scanning electron microscopy, fluorescence microscopy and fluorimetry, a custom-built acoustic setup, and clinical ultrasound. The GQD microbubbles were sized between 1.4 and 1.9 µm (U = 1.90, C = 1.44, A = 1.72, Unloaded = 2.02 µm). The U-GQD microbubble exhibited a higher bubble concentration/mg PLA (<i>p</i> < .05) and the A-GQD microbubbles exhibited the greatest shift in zeta potential. Electron microscopy revealed smooth surfaces and a spherical shape, showing that the nanoparticle addition was not deleterious. The A-GQD microbubbles were specifically detectable using DAPI-filtering with fluorescence microscopy and had the highest TRITC-filtered fluorescence. The C-GQD microbubbles had the highest loading efficiency at 59.4% (<i>p</i> < .05), and the lowest max acoustic enhancement at 5 MHz (U = 19.8, C = 17.6, A = 18.9, Unloaded = 18.5 dB; <i>p</i> < .05). Additionally, all microbubbles were visible and susceptible to inertial cavitation utilizing clinical ultrasound. The A-GQDs showed promise toward improving the theranostic capabilities of the microbubble platform. They have imbued the most advantageous fluorescence capability and slightly improved backscatter enhancement while retaining all the necessary capabilities of an ultrasound contrast agent. Future studies will investigate the coloading potential of A-GQDs and drug within microbubbles.

Authors

Institutions

Publication Details

Journal
Ultrasonic Imaging
Published
2024-09-22
DOI
https://doi.org/10.1177/01617346241279112
Citations
1
Primary Topic
Carbon and Quantum Dots Applications
Type
article
Field-Weighted Citation Impact
0.12
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a Polymer Ultrasound Contrast Agent Incorporating Nested Carbon Nanodots

Margaret A. Wheatley, Matthew Shirley, John R. Eisenbrey, Ankit Patel et al.
1 citations
Ultrasonic Imaging
Carbon and Quantum Dots Applications
0.12
article

Development of a Polymer Ultrasound Contrast Agent Incorporating Nested Carbon Nanodots

Margaret A. Wheatley, Matthew Shirley, John R. Eisenbrey, Ankit Patel, Valeria Arango-Aliaga, Brian E. Oeffinger
article en
1 citations

Abstract

Polymer microbubbles have garnered broad interest as potential theranostic agents. However, the capabilities of polymer MBs can be greatly enhanced, particularly regarding the imaging performance and functional versatility of the platform. This study investigates integrating fluorescent carbon nanodots within polylactic acid (PLA) microbubbles. First, the formulations are characterized by their size, microbubble counts, zeta potential, and resonance frequency. Then, the fluorescence capabilities, nanoparticle loading, and acoustic capabilities are examined. Unmodified (U-), carboxylated (C-), and aminated graphene quantum dots (A-GQDs) were separately suspended and synthesized at a 2% w/w ratio with PLA in the organic phase of the water/oil/water double emulsion process. The new microbubbles were characterized using an AccuSizer, Zetasizer, scanning electron microscopy, fluorescence microscopy and fluorimetry, a custom-built acoustic setup, and clinical ultrasound. The GQD microbubbles were sized between 1.4 and 1.9 µm (U = 1.90, C = 1.44, A = 1.72, Unloaded = 2.02 µm). The U-GQD microbubble exhibited a higher bubble concentration/mg PLA (<i>p</i> < .05) and the A-GQD microbubbles exhibited the greatest shift in zeta potential. Electron microscopy revealed smooth surfaces and a spherical shape, showing that the nanoparticle addition was not deleterious. The A-GQD microbubbles were specifically detectable using DAPI-filtering with fluorescence microscopy and had the highest TRITC-filtered fluorescence. The C-GQD microbubbles had the highest loading efficiency at 59.4% (<i>p</i> < .05), and the lowest max acoustic enhancement at 5 MHz (U = 19.8, C = 17.6, A = 18.9, Unloaded = 18.5 dB; <i>p</i> < .05). Additionally, all microbubbles were visible and susceptible to inertial cavitation utilizing clinical ultrasound. The A-GQDs showed promise toward improving the theranostic capabilities of the microbubble platform. They have imbued the most advantageous fluorescence capability and slightly improved backscatter enhancement while retaining all the necessary capabilities of an ultrasound contrast agent. Future studies will investigate the coloading potential of A-GQDs and drug within microbubbles.

Ultrasonic ImagingVol. 47(1)
Thomas Jefferson University (US), Drexel University (US)
Openalex Percentile: Top 60%
Carbon and Quantum Dots Applications
0.12
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.