Simulation of gamma reference field at Institute for Nuclear Science and Technology using Monte Carlo method

This paper presents the characterization of two gamma reference fields of 137Cs and 60Co sources at the Institute for Nuclear Science and Technology. The characterization of the fields in terms of gamma fluence Φ, mean energy, EΦ, kerma weighted mean energies, Eₖ, air kerma, Eair, were determined at various distances from the source center by Monte Carlo simulation using MCNP6. The air kerma results were compared with the measurements obtained by using a calibrated ionization chamber. The discrepancy between the simulated and measured air kerma was less than 4.5%. The scatterred component was also simulated and calculated. The results of both methods showed that the contribution of the scattered components to the gamma reference field is less than 3%. This contribution comply with the international standard criteria of ISO 4037 (<5%). The results confirmed that the characterization of the gamma reference field could be determined using the simulation code.

Authors

Publication Details

Journal
Nuclear Science and Technology
Published
2024-09-23
DOI
https://doi.org/10.53747/nst.v14i2.448
Primary Topic
Nuclear Physics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simulation of gamma reference field at Institute for Nuclear Science and Technology using Monte Carlo method

Thi Nhung Duong, Huu Quyet Nguyen, Thi My Linh Dang, Ngoc Quynh Nguyen et al.
Nuclear Science and Technology
Nuclear Physics and Applications
article

Simulation of gamma reference field at Institute for Nuclear Science and Technology using Monte Carlo method

Thi Nhung Duong, Huu Quyet Nguyen, Thi My Linh Dang, Ngoc Quynh Nguyen, Ky Bui Duc, Dang Nguyen Nguyen, Minh Hue Dang
article en

Abstract

This paper presents the characterization of two gamma reference fields of 137Cs and 60Co sources at the Institute for Nuclear Science and Technology. The characterization of the fields in terms of gamma fluence Φ, mean energy, EΦ, kerma weighted mean energies, Eₖ, air kerma, Eair, were determined at various distances from the source center by Monte Carlo simulation using MCNP6. The air kerma results were compared with the measurements obtained by using a calibrated ionization chamber. The discrepancy between the simulated and measured air kerma was less than 4.5%. The scatterred component was also simulated and calculated. The results of both methods showed that the contribution of the scattered components to the gamma reference field is less than 3%. This contribution comply with the international standard criteria of ISO 4037 (<5%). The results confirmed that the characterization of the gamma reference field could be determined using the simulation code.

Nuclear Science and TechnologyVol. 14(2)
Openalex Percentile: Top 79%
Nuclear Physics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Simulation of gamma reference field at Institute for Nuclear Science and Technology using Monte Carlo method — Thi Nhung Duong, Huu Quyet Nguyen, et al. · Nuclear Science and Technology (2024) | TGRS Research Map | TGRS