Optimizing and Improving Unified Power Quality (UPQC) for Mitigation of Voltage Drop

Now-a-days, Power system is progressively improving addicted to a power electronic based power system and survive various power quality issues, which encourages the expansion of active power filter (APF). APF has improved into a Unified Power Quality Conditioner (UPQC). Voltage drops and swells are universal power quality issues in 3-phase electrical distribution systems, causing equipment malfunction and process disruption. This paper proposes a UPQC to compensate power quality issues in a 3ph3w distribution system. The UPQC integrates a shunt and series active power filter (APF), linked nonstop via a DC-link capacitor. The series filter of the UPQC adds a proper voltage component to retain a constant sinusoidal voltage at the load terminal, whereas shunt filter handles fluctuations in power demand. The capability of the proposed method is evaluated through comprehensive simulation studies in MATLAB/Simulink and enhancing power quality and protecting sensitive loads. The implementation process of various considerations, including topology selection and control algorithm design; crucial for optimizing UPQC performance. Successful voltage regulation is achieved during specified voltage drop and swell.

Authors

Publication Details

Published
2024-08-08
DOI
https://doi.org/10.1109/iccpct61902.2024.10673022
Citations
2
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.42
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing and Improving Unified Power Quality (UPQC) for Mitigation of Voltage Drop

B M Jeevan, Fatima Unnisa, Kusuma Charan Chandra, Sanagala Naga Ranga Sai Viswanath et al.
2 citations
Power Quality and Harmonics
0.42
article

Optimizing and Improving Unified Power Quality (UPQC) for Mitigation of Voltage Drop

B M Jeevan, Fatima Unnisa, Kusuma Charan Chandra, Sanagala Naga Ranga Sai Viswanath, Nadimpalli Madana Kailash Varma
article en
2 citations

Abstract

Now-a-days, Power system is progressively improving addicted to a power electronic based power system and survive various power quality issues, which encourages the expansion of active power filter (APF). APF has improved into a Unified Power Quality Conditioner (UPQC). Voltage drops and swells are universal power quality issues in 3-phase electrical distribution systems, causing equipment malfunction and process disruption. This paper proposes a UPQC to compensate power quality issues in a 3ph3w distribution system. The UPQC integrates a shunt and series active power filter (APF), linked nonstop via a DC-link capacitor. The series filter of the UPQC adds a proper voltage component to retain a constant sinusoidal voltage at the load terminal, whereas shunt filter handles fluctuations in power demand. The capability of the proposed method is evaluated through comprehensive simulation studies in MATLAB/Simulink and enhancing power quality and protecting sensitive loads. The implementation process of various considerations, including topology selection and control algorithm design; crucial for optimizing UPQC performance. Successful voltage regulation is achieved during specified voltage drop and swell.

Affordable and clean energy
Openalex Percentile: Top 38%
Power Quality and Harmonics
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Optimizing and Improving Unified Power Quality (UPQC) for Mitigation of Voltage Drop — B M Jeevan, Fatima Unnisa, et al. · (2024) | TGRS Research Map | TGRS