Seismic Behavior of Precast Prestressed Concrete Frame with Hinge-Relocated Mortise–Tenon Connections

To satisfy the easy-construction demands of precast concrete (PCa) frames after an earthquake, a PCa frame with mortise–tenon (MT) connections is proposed in this paper. MT connections are secured solely through the binding force of unbonded prestressed tendons without grouting for easy construction. The design and construction of the joint are detailed. During an earthquake, the hinge system of the connection allows for slight rotational movements. Finite element analysis was employed to assess the joint’s hysteresis behavior, revealing a three-stage earthquake response mechanism: closing, hinge relocation, and self-centering. Based on the hysteresis performance of the beam and column in the precast prestressed concrete (PCaPC) frame, a seismic response model for PCaPC buildings was established.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2024-09-22
DOI
https://doi.org/10.3390/buildings14093007
Citations
2
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.53
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Seismic Behavior of Precast Prestressed Concrete Frame with Hinge-Relocated Mortise–Tenon Connections

Noriyuki Takahashi, Hanxi Zhao
2 citations
Buildings
Structural Behavior of Reinforced Concrete
0.53
article

Seismic Behavior of Precast Prestressed Concrete Frame with Hinge-Relocated Mortise–Tenon Connections

Noriyuki Takahashi, Hanxi Zhao
article en
2 citations

Abstract

To satisfy the easy-construction demands of precast concrete (PCa) frames after an earthquake, a PCa frame with mortise–tenon (MT) connections is proposed in this paper. MT connections are secured solely through the binding force of unbonded prestressed tendons without grouting for easy construction. The design and construction of the joint are detailed. During an earthquake, the hinge system of the connection allows for slight rotational movements. Finite element analysis was employed to assess the joint’s hysteresis behavior, revealing a three-stage earthquake response mechanism: closing, hinge relocation, and self-centering. Based on the hysteresis performance of the beam and column in the precast prestressed concrete (PCaPC) frame, a seismic response model for PCaPC buildings was established.

BuildingsVol. 14(9)
Tohoku University (JP)
Openalex Percentile: Top 34%
Structural Behavior of Reinforced Concrete
0.53
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.