Axial Compression Performance of L-Shaped Partially Encased Steel–Concrete Composite Stub Columns

The L-shaped partially encased steel–concrete composite (PEC) stub column, composed of profile steel, concrete, and transverse links, tends to occupy less space than the rectangle-shaped PEC column when used as side or corner columns. In this study, an axial compression test involving three L-shaped PEC stub columns was conducted to investigate the influence of critical factors on axial compression performance. The test results indicated that the axial compression capacity can be effectively enhanced with an increase in material strength. Furthermore, finite element (FE) analysis was carried out with parameters such as material strength, steel thickness, transverse link spacing, transverse link diameter, transverse link distribution, and longitudinal rebar diameter. The results revealed that the primary failure modes of L-shaped PEC columns were concrete spalling and local buckling of the flange. Additionally, it was found that the increase in steel strength, steel thickness, and transverse link diameter, as well as the decrease in transverse link spacing, significantly improved the axial compression capacity and concrete confinement effect. However, an increase in concrete strength diminished the concrete confinement effect. Additionally, the accuracy of the axial compression capacity calculation methods in the Eurocode 4 and T/CECS719-2010 specifications for L-shaped PEC stub columns was verified. Finally, a calculation method based on the superposition principle incorporating the concrete confinement effect was proposed, and validated by comparing with experimental and FE results. Overall, this study could provide a theoretical basis for the engineering application of L-shaped PEC columns.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2024-09-21
DOI
https://doi.org/10.3390/buildings14093001
Citations
2
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Axial Compression Performance of L-Shaped Partially Encased Steel–Concrete Composite Stub Columns

Youwu Xu, Zhibin Xiao, Zhenfen Jin, Hao-Chuan Zhu et al.
2 citations
Buildings
Structural Load-Bearing Analysis
0.52
article

Axial Compression Performance of L-Shaped Partially Encased Steel–Concrete Composite Stub Columns

Youwu Xu, Zhibin Xiao, Zhenfen Jin, Hao-Chuan Zhu, Yuan-Sen Qi
article en
2 citations

Abstract

The L-shaped partially encased steel–concrete composite (PEC) stub column, composed of profile steel, concrete, and transverse links, tends to occupy less space than the rectangle-shaped PEC column when used as side or corner columns. In this study, an axial compression test involving three L-shaped PEC stub columns was conducted to investigate the influence of critical factors on axial compression performance. The test results indicated that the axial compression capacity can be effectively enhanced with an increase in material strength. Furthermore, finite element (FE) analysis was carried out with parameters such as material strength, steel thickness, transverse link spacing, transverse link diameter, transverse link distribution, and longitudinal rebar diameter. The results revealed that the primary failure modes of L-shaped PEC columns were concrete spalling and local buckling of the flange. Additionally, it was found that the increase in steel strength, steel thickness, and transverse link diameter, as well as the decrease in transverse link spacing, significantly improved the axial compression capacity and concrete confinement effect. However, an increase in concrete strength diminished the concrete confinement effect. Additionally, the accuracy of the axial compression capacity calculation methods in the Eurocode 4 and T/CECS719-2010 specifications for L-shaped PEC stub columns was verified. Finally, a calculation method based on the superposition principle incorporating the concrete confinement effect was proposed, and validated by comparing with experimental and FE results. Overall, this study could provide a theoretical basis for the engineering application of L-shaped PEC columns.

BuildingsVol. 14(9)
Zhejiang Province Institute of Architectural Design and Research (CN), Jiyang College of Zhejiang A&F University (CN), Zhejiang University (CN)
Openalex Percentile: Top 36%
Structural Load-Bearing Analysis
0.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Axial Compression Performance of L-Shaped Partially Encased Steel–Concrete Composite Stub Columns — Youwu Xu, Zhibin Xiao, et al. · Buildings (2024) | TGRS Research Map | TGRS